beautypg.com

Trouble shooting guide – Bonide Fog Rx Insect Fogger User Manual

Page 6

background image

5

18. DO NOT incinerate cylinders or insecticide vessel. Propane cylinder vessels

should be disposed of properly when empty.

Trouble Shooting Guide

Symptom

Probable Cause

Corrective Action

No fog - Burner works

1)

Spray tip and/or end of

heater coil obstructed or
clogged

1)

Remove Spray tip and check for
blockage. Clean spray tip to remove
blockage. With spray tip removed, use
a pipe cleaner to clear out carbon
build-up that may be inside the burner
coil. Replace spray tip and tighten
securely.

2) Pump plugged

2)

Remove Insecticide Vessel. With
fogger on its side, carefully remove
Plastic Pump Assembly Cover (be
aware of spring & bearing inside cover)
from fogger. Insert a small wire into
hole in bottom of Pump Assembly
(clearing any blockage). Carefully
replace Plastic Pump Assembly cover
with spring & bearing inside.

3) Piston cup worn

3)

See parts & service on next page

4) Improper fogging material

4)

Use only insecticide for thermal
fogging

No fog-burner not
working

1)

Propane cylinder empty

1)

Replace propane cylinder

2)

Propane tank attached

improperly

2)

Check to see if propane cylinder is
properly attached

3)

Burner assembly fails to

light or will not stay lit

3)

Check igniter. Test lighting unit using
a match.

Dripping

1)

Spray tip loose

1)

Tighten spray tip securely

2)

Excessive insecticide output

2)

Decrease your pumping rate.

3)

Not at operating temperature

3)

Wait 60 seconds before pumping

Poor fog quality

1)

Improper fogging material

1)

Use only Bonide insecticide

2)

If fog is thin or yellowish

pumping rate is too low

2)

Increase your pumping rate.

3)

If fog is wet and dripping.

3)

Decrease your pumping rate

Flare up or un-
controlled burning

1)

Fogger pointed toward the

ground

1)

Always operate your fogger level with
ground. New propane bottles may be
more likely to flare.

2)

Insecticide ignited

2)

Stop pumping immediately. Turn
propane valve off. Flame will stop after
excess insecticide is eliminated

Piezo ignitor will not
spark

Ignitor broken or worn out

Replace ignitor