Hour, Test, Stby – Blizzard Lighting Q Flurry(Rev C) User Manual
Page 13: Auto, Soun, A001, Page 13
![background image](/manuals/584048/13/background.png)
Page 13
Flurry Q Manual Rev. C
Copyright (c) 2011-12 Blizzard Lighting, LLC
TO DISPLAY FIXTURE RUNNING HOURS:
1.) Press the button until the display shows
hour
2.) Press
TO SET THE FIXTURE IN TEST MODE:
1.) Press the button until the display shows
TEST
2.) Press
TO SET THE LED DISPLAY MENU ON/OFF AFTER 5 SECONDS:
1.) Press the button until the display shows
LED
2.) Use the <+/-> buttons to set to the desired position,
press
TO SET THE STANDBY MODE OF THE FIXTURE (when not receiving DMX
signal):
1.) Press the button until the display shows
STbY
2.) Use the <+/-> buttons to set to the desired position,
press
Stand-Alone Mode (Auto or Sound Active Mode):
Allows a single unit to run to a factory installed program.
1.) Press the button until it shows
AuTo
or
SouN
and
press
2.) Use the <+/-> buttons to set to the desired position,
press
Master/Slave Mode (Auto or Sound Active):
Allows you to link up to 32 units together without a controller.
1.) Use standard DMX cables to daisy chain your units together via the DMX con-
nector on the rear of the units. It may be necessary to use a terminator at the
last fixture. For more information about terminators, see page 8.
2.) Choose a unit to function as the Master. Select NAST/SL 1 or SL 2 depending
upon which master / Slave mode you want. Slave 1 mode causes all fixtures to
react the same. Slave 2 mode causes those fixtures to react in a complimentary
way to those set as master / Slave 1. The master unit must be the first unit.
Finally, chain the units together using DMX cable.
DMX Mode
Allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with
DMX, please read the DMX Primer on page #17.
1.) The default mode for the fixture is DMX, which appears as
A001
on the LED
Readout.