5. If the resistance is less than 10k Ohms, then disconnect
the main connector from the processor and recheck
the resistance on the blue wire. If the resistance is
still less than 10k Ohms then a short may exist in the
wiring harness (a screw may have been driven in to
the wire). If the resistance is greater than 10k Ohms
then temporarily replace the processor with a known
good unit and re-test.
6. Reconnect the main connector to the processor
and recheck the resistance on the blue wire. If the
resistance is greater than 10k Ohms then temporarily
replace the processor with a known good unit and
re-test
ADDITIONAL SUPPORT AT
WWW.BENDIX.COM/1-800-AIR-BRAKE (1-800-247-2725, OPTION 2)
For the latest information, and for free downloads of the Bendix
®
ACom
®
Diagnostics
software, and its User Guide, visit the Bendix website at: www.bendix.com.
For direct telephone technical support, the Bendix Tech Team is available at 1-800-AIR-
BRAKE (1-800-247-2725, option 2) Monday through Friday, 8:00 A.M. to 6:00 P.M. ET.
Follow the instructions in the recorded message.
The Bendix Tech Team can also be reached by e-mail at: [email protected].
3.5 CLEARING DIAGNOSTIC
TROUBLE CODES (DTCS)
Once the problem has been found and resolved, clear the