Side sensor not detecting targets – Bendix Commercial Vehicle Systems BLINDSPOTTER TROUBLESHOOTING GUIDE User Manual
Page 18

3-6
Symptom Isolation Procedures
Side Sensor Not Detecting Targets
Step A
Procedure
Condition
Action
Step B
Procedure
Condition
Action
Step V
Procedure
Condition
Action
1. Clear area around sensor of
objects.
2. Key on.
3. Allow Operator Display
Unit to go through self-
test and shows no 
targets (yellow LED 
light should be on).
1. Key on.
2. Place a target 3 to 10
feet directly in front of 
the Sensor.
1. Key off.
2. Reconnect all connectors.
3. Drive vehicle to
determine if problem 
has been corrected.
If both LED lights turn on 
for .5 seconds – followed by 
red LED for 5 seconds – 
followed by a continuous 
yellow light
If only the yellow LED light 
turns on for .5 seconds, 
followed by a continuous 
yellow light
If both LED lights turn on 
for .5 seconds, followed by 
continuous yellow and red 
lights
If the Operator Display Unit 
indicates that a target is 
detected (red light on)
If the Operator Display Unit 
does not indicate a target is 
present (yellow light on)
If complaint has been 
repaired
If complaint has not 
been repaired
Go to Step B.
Replace Operator Display Unit.
Go to the “Power-Up Sequence 
Test” on page 2-4.
Go to Step V.
Replace sensor.
Test complete.
Return to Step A to fi nd 
error in testing.