TROUBLESHOOTING
PROBLEM
PROBABLE CAUSE
WHAT TO DO
Build up of fluid upon
register table
1. Improper setting of nozzle
Readjust nozzle between register
within nozzle holder
tape drive roller and register table
Inconsistent Folds
1. Positioning of WetScore
Readjust to proper position
needles is out of register
2. Poor or no flow from
See above
needles
3. Folder plate stop set off of
Readjust to proper position
proper position
4. Alignment ofWetScore needle to
Realign the WetScore needle to the
mechanical score is improper
mechanical score
Ink is offseting along the
folded edge
1. Sheet coating is to dense for
Use of WetScore is not recommended
absorbtion of alcohol solution,
alcohol is breaking down the ink
Solution leaks from control
valve port
1. PVC tubing hardened
Replace, see instructions
and brittle
2. Control valve has
Replace
cracked
Needles do not shut off
1. Sensor is set to low
Adjust sensor so that the LED light is
off when sheet is absent
Discoloration of signatures
along scored edge
1. Paper stock is highly alkaline
Reduce the amount of alcohol in
(acid free paper)
solution to approx. 30%