SERVICING INSTRUCTIONS (continued)

REPLACE HEATING ELEMENT


Remove tank cover assembly (see page 13).


Remove two hex nuts holding element to cover. Pull element
from mounting holes.


Reassemble in reverse order.

REPLACE SOLENOID


Symptom: Automatic brewer will not flow water; or,
automatic brewer drips continuously from brew head.


Unplug power cord or turn circuit breaker OFF. Turn water
supply OFF.


Remove top panel.


Disconnect wiring from solenoid.


Unscrew water inlet piping from solenoid.


Remove two screws holding solenoid to bracket.


Remove brew and dilution manifold from solenoid, transfer
components to new solenoid


Transfer solenoid bracket to new solenoid.


Reassemble in reverse order.

REPLACE TIMER ASSEMBLY


Unplug power cord or turn circuit breaker OFF.


Remove top panel. Remove knob and three screws holding timer
to bracket. Disconnect wiring to timer.


Reassemble in reverse order.
Adjust timer as described on page 13

CLEAN STRAINER SCREEN


Unplug power cord or turn circuit breaker OFF. Turn water
supply OFF.


Remove bottom cap from strainer. Withdraw filter screen from
strainer body.


Clean screen with a suitable brush.


Reassemble in reverse order.

IMPORTANT: When replacing
heating element, also replace
seal gaskets.

14

Fig. 12 Water Line Strainer