Test the vacuum system for leakage routinely, as directed in the preceding I

NSPECTION

and

T

ESTING

S

CHEDULES

.

1) Clean the face of the vacuum pad as previously directed (see V

ACUUM

P

AD

M

AINTENANCE

:

Cleaning).

2) Attach to the pad a test load with a clean, smooth, flat and nonporous contact surface. The

test load must be fully and independently supported; do not rely on the product to support

the test load during the vacuum test.

3) When the vacuum level registers above 16" Hg [-54 kPa] on the vacuum gauge, turn the

power off and leave the load attached to the pad.

4) Monitor the vacuum gauge:

The vacuum level should not decrease by more than 4" Hg [-14

kPa] in 10 minutes.

WARNING: If product fails vacuum test, discontinue use immediately.

Correct any deficiency in the vacuum system before using the product. Contact Wood’s Powr-

Grip or an authorized dealer for assistance.