Operation, Efore, Sing the – Wood’s Powr-Grip FL4HV11AC User Manual
Page 11: Ifter, Taking safety precautions, Performing inspections and tests, Olding, Rms and, Hutoff

Rev 15.0/1-14
9
FL4HV11AC: #35030
OPERATION
B
EFORE
U
SING THE
L
IFTER
The operator must determine whether the lifter is capable of performing each intended task, in
accordance with the SPECIFICATIONS and INTENDED USE sections of this
INSTRUCTIONS
manual. In addition, all of the following preparations must be completed prior to lifting any load.
Taking Safety Precautions
The operator must be trained in all relevant industry and regulatory standards for the operation
of the vacuum lifter in its geographical location (eg, ASME B30.20 in the USA).
The operator must read and understand this
INSTRUCTIONS
manual, including all
WARNINGS
,
before using the lifter. If necessary, contact Wood’s Powr-Grip or an authorized dealer for
assistance.
WARNING: Always wear appropriate personal protective equipment.
The operator must wear any personal protective equipment and take any other precautions
required to handle the load safely. Consult appropriate trade association guidelines to determine
what precautions are necessary for each type of load material.
Performing Inspections and Tests
Perform all inspections and tests required by the I
NSPECTION
and T
ESTING
S
CHEDULES
(see
MAINTENANCE). In addition, if the lifter has been in storage, always conduct a V
ACUUM
T
EST
before placing it in service (see MAINTENANCE).
CAUTION: Examine each air filter regularly, and empty when necessary.
The lifter is equipped with one or more air filters to help protect the vacuum system from
contaminants.
4
In order for a filter to function, the operator must empty the filter bowl before
enough liquid accumulates to contact any portion of the filter element (see MAINTENANCE: A
IR
F
ILTER
M
AINTENANCE
).
T
O
U
SE
F
OLDING
A
RMS AND
P
ADS
S
HUTOFF
Depending on the positions of the folding pad arms and the pads shutoff, the lifter can
accommodate loads of various dimensions and weights (see Pad Spread and Load Capacity in
SPECIFICATIONS): For loads greater than 60" [152 cm] long and weighing up to 1000 lbs [455
kg], the pad arms must be folded down and all four vacuum pads must be activated. For smaller
loads, the pad arms can be folded up and the outer two pads can be deactivated,
provided that
the lifter still has sufficient capacity to support the load
(see INTENDED USE: L
OAD
4
In order for the operator to use the lifter on wet load surfaces, it must be equipped with 2 or more filters that are connected
in
series. However, see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient before using the lifter on wet load surfaces.