beautypg.com

Elease the, Ad from the, Fter – Wood’s Powr-Grip FL1HV11DC User Manual

Page 16: Sing the, Ifter, Storing the lifter

background image

Rev 3.0/9-13

14

FL1HV11DC: #35026

T

O

R

ELEASE THE

P

AD FROM THE

L

OAD

WARNING: Load must be fully supported before releasing vacuum pad.

When the load is at rest and fully

supported, pinch the valve release lever
against the valve handle, to unlatch the
handle. Then push the valve handle

inward to the “RELEASE” position (power
off), as shown. Do not attempt to move
the lifter until the vacuum pad disengages

completely from the load.

A

FTER

U

SING THE

L

IFTER

Leave the valve handle in the “RELEASE” position (power off).

CAUTION: Do not set the lifter against any surfaces which could soil or damage the

vacuum pad.

Use the hoisting equipment to gently lower the lifter onto a stable support; then detach the

hoisting equipment hook from the lift bail.
If the lifter is transported to another location, use the original shipping container and secure the

lifter so as to protect the vacuum pad and all other components from damage while in transit.

Storing the Lifter

Use the cover supplied to keep the vacuum pad clean.

!!-CE-!! In accordance with CE Standard EN 13155, the lifter is designed to rest on relatively

horizontal surfaces without tipping over. To store the lifter in this way, set the lifter with the pad
facing downward on a clean, smooth, flat surface.

Charge the battery completely when placing it in storage and at six-month intervals thereafter

(see MAINTENANCE: B

ATTERY

R

ECHARGE

). After charging the battery, disconnect the electrical

connectors uniting the battery to the battery charger and to the vacuum generating system, in
order to minimize power drainage. Preferred temperatures for storing the battery are 32° to 70°

Fahrenheit [0° to 21° Celsius]. Higher temperatures require the battery to be charged more
frequently. Storage at temperatures above 100° Fahrenheit [38° Celsius] should be avoided.

TO RELEASE