3

PT10FS10TAIR: #35143

SPECIFICATIONS

Model Number:

PT10FS10TAIR(O) or PT14FS10TAIRO

Description:

Designed for use with a crane or other hoisting equipment, all variations of the
PT10FS10TAIR lifter employ vacuum to hold a load for lifting, and they provide

powered 90° tilt movement for load manipulation.

Power Source:

Compressed air, 80-150 psi [550-1035 kPa] line pressure, 11 SCFM [311 liters/minute]
@ 80 psi [550 kPa]

Vacuum Pads:

10" [25 cm] nominal diameter (Model VPFS10T), standard rubber, spring-mounted (¼"

[7 mm] travel), with #60 filter screen and replaceable closed-cell foam rings for
applications on rough or textured surfaces.

Pad Shutoffs:

Manual valves control vacuum flow at adjacent pads.

Pad Spread:

(to outer edges)

(w/10 pads - standard)

(w/10 pads - optional)

(w/14 pads - optional)

Minimum:

23¾" x 11¾"

[603 x 298 mm]

11¾" x 32¾"

[298 x 832 mm]

11¾" x 31½"

[298 x 800 mm]

Maximum:

23¾" x 74¾"

[603 x 1899 mm]

33¾" x 74¾"

[857 x 1899 mm]

60¾" x 90¾"

[1543 x 2305 mm]

Lifter Weight:

328 lbs [149 kg]

348 lbs [158 kg]

516 lbs [234 kg]

Load Capacity:

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad:

150 lbs [68 kg]

Note: Calculated lifting capacities cannot

Maximum:

1500 lbs [680 kg]

exceed Maximum Load Capacity.

Tilt Capability:

Powered, 90°, continuous-duty type with adjustable-flow valves to control tilt speed;

Standard speed = approx. 8 seconds per tilt travel in one direction.

2

Vacuum Pump:

Venturi type, 4 SCFM [113 liters/minute] nominal vacuum flow @ 80 psi [550 kPa]

Vacuum Reserve Tank:

Vacuum reservoir helps prevent immediate vacuum loss in case of power failure.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.

Options:

Available

with Model CF9ADO - Alternative Dimension Pad Frames. These options

enable a lifter to handle loads with different dimensions from those of the standard pad
frame.

Available

with Model LB9HEO - Control Handle Extensions. This option moves the

control handle 36" [91 cm] outward from the standard position, enabling the operator

to maintain control of the lifter while remaining outside the path of tilting loads.
See separate instructions about other optional features.

Operating Elevation:

Maximum = 10,000 feet [3048 meters]

Operating Temperatures: 0° to 120° F [-18° to 49° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when used

and maintained as intended. Vacuum pads, filter elements and other wear-out items
are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more

information. For the D

ISPOSAL OF THE

L

IFTER

after its service life, see INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more information)

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS manual only when requirements of a CE Standard are different from

requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.

2

If the tilt speed is unsatisfactory, it can be adjusted as directed under T

ILT

C

OMPONENTS

M

AINTENANCE

: Tilt Speed Valves (see

MAINTENANCE).