beautypg.com

Hutoffs, Pply the, Ads to a – Wood’s Powr-Grip PT10FS10TAIR User Manual

Page 12: Powering up the lifter

background image

Rev 12.0/3-13

10

PT10FS10TAIR: #35143

T

O

U

SE

P

AD

S

HUTOFFS

Each shutoff on the pad frame controls the vacuum line to the adjacent vacuum pad. By

activating or deactivating the vacuum flow at specific pads, the operator can use the lifter to
handle loads of various weights and dimensions (see Load Capacity and Pad Spread in
SPECIFICATIONS). In addition, certain pads may be deactivated in order to avoid holes in the

load surface. To support the maximum load weight and larger load dimensions, all pads must be
activated; for smaller weights and dimensions, some pads may be deactivated,

provided that

the lifter still has sufficient capacity to support the load

(see INTENDED USE: L

OAD

C

HARACTERISTICS

).

WARNING: Closing any pad shutoff reduces lifting capacity.

To activate a pad, open the pad shutoff (place valve lever

parallel

with

vacuum line); to deactivate a pad, close the pad shutoff (place valve lever

perpendicular

to vacuum line). To calculate the lifting capacity when some

pads are deactivated, consult the Per-Pad Load Capacity rating (see

SPECIFICATIONS) and multiply by the number of pads currently
activated.

Note that calculated capacities may not exceed the

Maximum Load Capacity

(see SPECIFICATIONS). Always activate

pads in a symmetrical configuration, to keep the lifter balanced while
lifting, and use as many pads as possible for each load being lifted, to maximize lifting capacity
and to minimize load overhang.

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Powering up the Lifter

Make sure the lever on the vacuum control valve is in the center position (see T

O

R

ELEASE THE

P

ADS FROM THE

L

OAD

: About Stand-by Mode to follow). Place the slide on the air supply valve in

the “ON” position, to engage the vacuum pump. The lifter is designed for the vacuum pump to
run continuously.

WARNING: Never place air supply valve in "OFF" position while operating lifter;

keep pump running throughout lift.

The air supply valve must remain in the “ON” position while operating the lifter. Placing the air

supply valve in the “OFF” position during lifter operation could result in the release of the load
and possible injury to the operator (see T

O

L

IFT AND

M

OVE THE

L

OAD

: In Case of Power Failure to

follow).

CLOSED

PAD SHUTOFF VALVE