WARNING: Before proceeding with any maintenance, disconnect power source.
If the vacuum pump takes too long to attain full vacuum, it may require maintenance (see
OPERATING FEATURES for location of pump). Replace the diaphragms, valve flappers or head
gaskets as necessary to obtain acceptable pump performance (see REPLACEMENT PARTS LIST).
Perform the following procedures on both heads of the pump.
Replacing a Diaphragm (1)
1) Remove the six head screws (14) and remove the head
(13).
2) Remove the four diaphragm hold-down screws (3) and the
diaphragm hold-down plate (2)
.
3) Replace the diaphragm (1) and reverse the above procedure
for reassembly.
Replacing an Intake Valve Flapper (6)
1) Remove the six head screws (14) and remove the head
(13).
2) Remove the intake valve flapper screw (4) and the intake
valve keeper (5).
3) Replace the intake valve flapper (6) and reverse the above
procedure for reassembly.
Replacing a Set of Exhaust Valve Flappers (9 &
10) and a Head Gasket (12)
1) Remove the six head screws (14) and remove the head
(13).
2) Turn the head upside-down and remove the five valve plate screws (7).
3) Lift out the valve plate (8) to access the exhaust valve flappers (9 & 10) and head gasket
(12).
22
4) Remove the exhaust valve flapper screw (11) and replace the exhaust valve flappers.
5) Replace the head gasket and reverse the above procedure for reassembly.
1 DIAPHRAGM
5 INTAKE VALVE KEEPER
10 EXHAUST VALVE FLAPPER (METAL)
2 DIAPHRAGM HOLD-DOWN PLATE
6 INTAKE VALVE FLAPPER (METAL)
11 EXHAUST VALVE FLAPPER SCREW
3 DIAPHRAGM HOLD-DOWN SCREWS
7 VALVE PLATE SCREWS
12 HEAD GASKET
4 INTAKE VALVE FLAPPER SCREW
8 VALVE PLATE
13 HEAD
9 EXHAUST VALVE FLAPPER (PLASTIC)
14 HEAD SCREWS
22
CAUTION: Depending on the product, the vacuum system may require the valve plate (8) to be rotated to an orientation
different from the one shown. When removing the valve plate, always take note of its orientation in the pump head (13), and
install the valve plate the same way during reassembly. In all cases, the valve plate must be oriented so that its intake hole is
matched with the head port that connects to the check valve.