Operation – Waldmann PULSE PIR version IV - with MFT, Typ I User Manual
Page 5

5
Operating Manual Light Control “PULSE PIR - Vers. IV with MFT”
ENG
In-factory setting
The lights are set in-factory so that
initially they can be operated with-
out changing the settings. To adapt
the light to your individual needs,
the parameterisation functions
(see page 8-23) can be changed
accordingly.
Operation
Restoring the in-factory
setting
To restore the default settings,
press one of the two keys [I or II]
while the power supply is switched
on.
The following functions are re-
stored:
- Parameterisation functions are
set to standard setting.
- All control parameters are set to
standard setting.
- All control and follow-up times
are set to standard setting.
- The burn-in time is deleted (func-
The burn-in time is deleted (func-
tion „OFF“)
Operating and
display elements
All operating and setting functions
can be carried out from the column
operating panel (Fig. 3) as well as
from the sensor operating panel
(Fig.4).
The functions and settings for
the column operating panel are
displayed via the light bar, the logo
background light and the LEDs [I
and II].
The functions and settings of the
sensor operating panel are dis-
played via both LEDs.
Note: If a column operating panel
is available, the LED display in
the sensor is automatically sup-
pressed.
Fig.3 (Column operating panel)
Fig. 4 (Sensor operating panel)
Key I
Logo
Light
bar
Key II
LED I
LED II
LED II
Key II
LED I
Key I
Sensor