beautypg.com

Troubleshooting, Parts list – Vigo VG02013 User Manual

Page 4

background image

4

TROUBLESHOOTING

PROBLEM

POTENTIAL CAUSE

CORRECTIVE ACTION

1 - Leaks from handle

2 - Insufficient flow rate

3 - Leak at connection points

4 - Loose faucet body

PARTS LIST -

For any parts needed but not shown, please contact Vigo Technical Support

PART

TOLL FREE: (866) 591 - 7792

E-Mail: [email protected]

www.vigoindustries.com

PART #

FINISH

SUPPLY DATE INDICATOR (INTERNAL USE ONLY)

1.A - Cartridge unseated
1.B - Cartridge defective

2.A - Dirty aerator
2.B - Clog in supply hose / line

3.A - Sprayer hose not tight
3.B - Flexible hose leaking at body or connection point

4. - Metal nut became loose

3.A - Remove sprayer and check integrity of the black washer.
Make sure the washer is seated properly and retighten.

2.B - Remove sprayer or supply line and flush lines

2.A - Remove and soak / clean with a non abrasive agent (i.e.
vinegar).

1.B - Contact Vigo Technical Support for replacement.

1.A - Remove cartridge from housing, wash thoroughly with hot

water and reseat in housing.

3.B - Tighten hoses. If this does not resolve the issue, remove
the flexible hose and rethread, checking to make sure the
connection is secure. Make sure to use pipe tape.

4. - From under the counter, use an adjustable wrench and
tighten the metal nut to the hollow pipe. Make sure the faucet is
perpendicular to the counter.

W

ST

78038

Sprayer

Handle Set Screw

Sedal Cartridge

Metal Braided Hose

Handle Lever

Pull Out Hose (black nylon)

74019

-

W

ST

W

78039A

78039C

W

ST

74040

-

W

74020

W

-

5 - Sprayer button stops working

5.A - Debris in aerator
5.B - Wear and tear on button

5.A - Remove and clean aerator.
5.B - Contact Vigo Technical Support for replacement.

Handle

78039B

W

ST