2.1.4 Temperature Detection

If the battery’s temperature is above 65°C when it is put on to charge, the charger goes into a fault
condition and waits until the battery cools down before going into fast charge. If the battery gets
above 65°C while charging, the charger will suspend the charge until the battery cools down, and
then go back into fast charge to complete.

2.1.5 Unattended Charging

The Charge Modules will detect open or shorted cells. If a defective cell is detected the CH0004 will
not start the charge cycle.

Once Charge is completed the CH0004 will maintain the battery being charged with a trickle charge
if battery is left connected to the CH0004.

In no event will a battery be overcharged using the CHARGING ALGORITHM of the CH0004.

2.1.6 Wide Range Input Voltage

Allows for operation from nearly any AC or DC power source likely to be encountered worldwide.

2.1.7 Conditioning Cycle

Automatic discharge/recharge function included. The conditioning cycle can be activated individually
per battery at operator’s option.

2.1.8 Equipment Provided

Provided with the CH0004 Charger/Conditioner is, an AC power cable and this technical manual.