Attery, Ischarge, Tart – Ultralife CH0004 User Manual
Page 10: 4 battery discharge, 5 start-up
CAUTION: Prior to charging any rechargeable battery, verify the type of
battery to be charged. The CH0004 consists of two charge modules and a
Control/Filter Board. The CH0004 will safely and completely recharge UBI-
2590/U, BB-2590, UBBL09 Li-ION, BB-390/U, BB-590/U, and UBBL02
batteries.
Battery
Description
Manufacturer
NSN
Charge Cycle
BB-390/U
Nickel Metal Hydride
12/24VDC
Bren-Tronics
6140-01-490-4317 4
hours
MAI-390
Nickel Metal Hydride
12/24VDC
Mathews & Associates
4
hours
BB-590/U
NiCad 12/24 VDC
Various
2.5 hours
MAI-590
NiCad 12/24 VDC
Mathews & Associates
2.5 hours
UBI-2590 Lithium-ion
Ultralife
6
hours
BB-2590/U Lithium-Ion
Bren-Tronics
6140-01-490-4316 6
hours
UBBL09
Lithium-ion
Ultralife
6 hours
UBBL02
UBI-2590 Lithium-ion
Ultralife
6140-01-553-3527
6 hours
NOTE: If a battery type is encountered which is not listed in the table above,
please contact Ultralife Corp at the address or E-mail provided throughout
this document.
3.4 Battery
Discharge
The CH0004 allows the operator to discharge batteries. During the discharge function the top heat
sink surface of the charger will become warm. This is normal operation. During discharge operation
locate the CH0004 in a well-ventilated area and ensure no flammable materials are near the unit.
3.5 Start-up
The CH0004 automatically determines the battery type connected. The operator can either plug the
CH0004 into a power source or attach the batteries to the unit first. Once the batteries are attached
and power applied to the unit, the batteries automatically start charging.
CH0004 Operation Manual
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2010 Ultralife Corporation • www.ultralifecorp.com • All specific subject to change without notice
The information contained herein is for reference only and does not constitute a warrant of performance •
30 SEP 10 UBI-5157 Rev: E
Page 10 of 15