Burnham MST396 User Manual
Page 21

1
Figure 10: Oil Burner Installation
f. Insert oil burner into the opening of burner
swing door. Align and engage keyhole slot in
burner flange over head of protruding cap screw
installed in previous Step. Rotate burner to the
right to lock flange behind head of cap screw.
g. Align holes and install two (2) remaining cap
screws. Level burner and fully tighten all three
(3) screws.
h. Plug burner power cord into power outlet
receptacle located in lower right corner of front
panel.