beautypg.com

Operating instructions, Operating your pellet stove, Opera tion – Regency Greenfire GFI55 Medium Pellet Insert User Manual

Page 8

background image

Greenfi re Pellet Stove and Insert Owner's Manual

8

OPERA

TION

OPERATING INSTRUCTIONS

OPERATING YOUR PELLET STOVE

PRE-BURN INSTRUCTIONS:

The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper

operation. Check the hopper for enough pellets to start the unit.

Note: The thermostat mode can be changed during normal operation.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

Figure 1: Thermostat Switch in

MANUAL position.

Figure 2: Thermostat Switch in

HIGH/LOW position.

Figure 3: Thermostat Switch in

ON/OFF position.

HIGH/LOW MODE: (Requires a thermostat)

INITIAL START-UP: See manual mode above.

OPERATION: When the thermostat calls for heat (contacts are closed) the stove settings are
adjustable as per Manual Mode. When the thermostat contacts open, the HEAT LEVEL and Fans
will drop down to the LOW setting until the thermostat contacts close again. *The LOW heat
setting can be adjusted for different fuel qualities (see “O

PERATING

I

NSTRUCTIONS

- C

ONTROL

B

OARD

F

UNCTIONS

”). The stove will come back to the previous HEAT LEVEL setting when the thermostat

contacts close again.

AUTO/OFF MODE: (Requires a thermostat)

INITIAL START-UP: See manual mode above.

OPERATION: When the thermostat contacts close, the unit will light automatically. Once up to
temperature, the stove operates the same as in MANUAL. When the thermostat contacts open, the
stove’s HEAT LEVEL and Fans will drop down to the LOW setting for 30 minutes. If the thermostat
contacts close within the 30 minutes, the HEAT LEVEL will return to the previous MANUAL setting.
If the thermostat contacts remain open the stove automatically begins its shutdown routine. The
ON / OFF button can be presses at any time the the stove will immediately shut down. The stove
will re-light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

• MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will

stop the feed of pellets. The blowers will continue to operate and cool the stove down. When
cool enough, the stove will turn off.

• AUTO / OFF mode: To turn the unit OFF, turn the thermostat down or off. NOTE: The unit will run

on low for three (3) minutes before it turns off.

DO NOT unplug unit while Combustion fan is operating.

This may lead to smoke escaping from the stove.

MANUAL MODE:

All control of circuit board function is adjusted at the circuit board.

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The
Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during
start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up
and can be adjusted but the change will not take affect until the start -up has finished.

To PRIME AUGER: If this is the first time the unit has been started or the unit has run out of fuel,
the auger will need to be primed. This can be done by restarting the unit five (5) minutes into its
start-up or by putting a small hand full of pellets into the burnpot.

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately
10 - 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the
setting of the heat level output indicator. The convection blower can be turned off by depressing the
room air on/off button. For the best efficiency and to prevent cycling the convection blower should
be left on at all times.

This manual is related to the following products: