beautypg.com

Safety label, Caution, Attention – Regency Greenfire GFI55 Medium Pellet Insert User Manual

Page 4: Inst alla tion

background image

Greenfi re Pellet Stove and Insert Owner's Manual

4

INST

ALLA

TION

SAFETY LABEL

This is a copy of the label that accom-
panies each GF55 & GFI55. We have
printed a copy of the contents here for
your reference.

On the GF55 the safety label is located
on the underside of the hopper lid.

On the GFI55 the safety label is located
on the hopper cover behind the top
faceplate.

To

P

rim

e

A

uger: Restar

t the u

nit five (

5) m

inutes into i

ts startup

or b

y putti

ng a sm

all hand f

ul

l of pell

ets into the bur

npot.

To

Operate

Stove: MANU

AL

MODE: When a fire has been

establi

shed the stove settings ar

e adj

ustabl

e. / HIGH

/LOW MOD

E:

(Requi

res a therm

ostat

) W

he

n

the the

rmostat cal

ls for heat the

stove sett

ings are adjustable. When th

e ther

mostat contacts op

en, the HE

AT

LE

VEL

and Fans

w

ill dr

op down

to the LOW

setti

ng u

nti

l t

he thermostat

contacts close agai

n. /

AUT

O/OFF MODE

: (

R

equires a ther

mostat

)

When th

e ther

mostat contacts

cl

ose, th

e

unit wi

ll light

autom

atical

ly

. Once up to te

mperatur

e the stove set

tings are adjustable. When th

e ther

mostat

contacts op

en, the stove will

drop down t

o the LO

W

set

tin

gs for

30 minutes.

If within

the

30 min t

he thermostat contacts

close,

the HEA

T

LE

VEL

will r

eturn to

pr

evi

ous

MAN

UAL

setting or if the the

rmost

at

con

tacts rem

ai

n

open the stove beg

in it

s shutdown r

ou

tin

e.

To

T

ur

n Of

f Stove: M

A

NUA

L and HI / L

OW mode: P

ress the ON

/ OFF button

AUT

O

/

OFF m

ode

: Tu

rn th

e ther

mostat down or of

f

The unit can

be installed on a

hard,

stable

non-com

bustibl

e surface.

L'uni

té peut être

inst

al

lée

sur

un dur

,

la sur

face non-combusti

ble

stable.

Cer

tifi

ed f

or

us

e

in Can

ada & USA

Cer

tifié pour

in

stall

at

ion

a

u

Can

ada et

aux

Etat

s-

Unis

.

Listed Roo

m

Hea

ter

, Pelle

tized F

uel T

ype

(Apparei

l de chauf

fage à granule

s certif

ié)

S

uitable

Fo

r Mobile

Home

Installat

ion (

A

ccepté

pour

l'in

st

allation

dan

s une

maiso

n

mobile,

test)

Te

st

ed

to (

Te

stée selo

n)

:

U

L

14

82

-1

9

98

/ UL

C S

6

27

-00

/ A

S

T

M

1

50

9-

9

5 /

UL

C

S

628

-M

93

US Envir

onmental

P

rotection Age

ncy, certif

ied t

o comply July 1, 1

990,

particulate

emission

st

and

ar

ds. (

É

tats-Unis E

nvironne

m

en

tal

P

rotection Ag

ence,

a cert

ifi

é

pour

conform

er

au Juil

let

1,

1990

, les normes de

particules

d'émission.)

This pel

let

appliance

ha

s been t

est

ed and l

ist

ed

for use

in m

anufactured hom

es

in

ac

cordanc

e with O

regon

A

dmini

st

ra

tion Rules 8

14-23-

900

throug

h

814-

23-909.

Instal

l and

use

only

in accord

ance

wit

h the

Manuf

ac

tur

e’

s

ins

tall

ation

and opera

ting

instructi

ons. Cont

act

local bui

lding

or

fi

re off

icials

about r

estrictions and

install

ati

on inspecti

on i

n

your

ar

ea.

Do

not con

nect

this uni

t to a chimney

flue

ser

ving another

appli

ance. See

local buildi

ng

codes

and

manuf

ac

tur

ers i

ns

tru

ctions f

or

pr

ecauti

ons requ

ired

for passing

a

chim

ne

y

through a com

bus

tibl

e

wal

l or cei

ling.

El

ec

tr

ical

rating:

120 volt

s,

60 hz,

4.3

Am

ps

. R

oute cord away from t

he heat

er

.

Cet

appa

reil

a

été t

esté et

certi

fié pour

uti

lisat

ion dans les m

aisons mobi

les en

ac

cord avec l

es "Règles

Adm

inistr

at

ives

de l'O

regon

814-23-

900

à 814-23

-909"

. Install

ez et

uti

lis

ez ce

t appareil

seulement

selon les i

nstruc

tions d'

instal

lation et

d'opérati

on du f

abr

ican

t.

Contact

ez les

autorités locales de

votre quar

tier concer

nant

le

s r

estr

ic

tions et

les inspecti

ons

d'i

ns

tall

ation. Consul

tez l

es

codes

de bât

iment

loc

aux et

les i

ns

tr

uct

ions du fabricant

pou

r

les préc

autions à

pr

endre

lorsqu

e

une chemi

née doit êt

re instal

lée au traver

s un mur ou u

n plaf

ond

combusti

ble.

CLASS

EMENT

ÉLECTR

IQU

E :

120 V

olt

s,

60

Hz,

4.1

Amps.

Pl

acez

le câble

électr

ique

loin de l

a chaleur

.

F

or

Use With

Onl

y

Pell

etized

W

ood

fuels. Operate

only w

ith viewi

ng

door

and ash removal

door

closed. Only

replace

gl

as

s

wit

h ceramic

glass.

Components r

equired f

or

instal

lat

ion:

a 3

inch (75 m

m)

or

4inch (100 m

m) l

isted

PL vent,

compl

ete

wit

h components.

Ins

ert

and Hearth

mount

inst

allat

ions;

a l

isted single

wall

chim

ne

y

line

r m

ay be u

sed.

Inspect

and clean

Exhaus

t V

ent

ing

system fre

quent

ly.

Uti

lisat

ion avec l

es combust

ibles

sous

forme de boulets

uniquement

. Uti

liser seulem

ent l

or

sque les portes avant

s

et

la

porte du réc

ept

acle de

cend

re sont

fer

m

ées.

Si

une ou des vit

res de

vai

ent êtr

e r

em

placées,

util

isez seulem

ent

du

ver

re

céramique. Les com

posantes

r

equi

se

s

pour

l'i

nstall

ation

sont u

n

évent

PL

cer

tif

de 3in/75mm or

4in/

100m

m

av

ec

ses

composantes.

Les i

ns

tall

ations

inser

tion

et

de

mont

de foyer

;

un

paquebot

de

cheminée de mur de

seul énum

йr

й pe

ut

être ut

ili

sé.

Input

Rating

(Les données

évaluant):

12,000 to 45,

000

BTU/

Hr (3.5 to 13.2

kWh)

334

DATE OF M

ANUFACTUR

E /

D

ATE DE FABRICATIO

N:

J F M A M J J A S O N D 20

09 20

10 20

11

CAUTION:

Hot while operating. Do not

touch, severe burns may

resu

lt.

Ke

ep children

, cl

o

th

ing

,

furniture, gaso

line or o

th

er

fla

m

mab

le vapo

rs

away

.

A

TTENTION:

T

rès

ch

aud quan

d a

llumé.

Ne touc

hez pas,

les brûlures sévères peuv

ent résu

lter.

Tene

z loin d

es e

nf

a

nts, des vêtements, de

s

meubles,de l’esse

nce ou d’autr

e

s flu

id

es

p

ro

duisant d

es vapeurs in

flammables.

DO NOT REMOVE THIS LABEL /

NE

RETIREZ P

A

S

CETTE

ÉTIQUETTE

See installation and operating instructions accompanyi

ng appliance. /

Co

nsultez le m

anuel avec le

s instructions d’installation et d’opérat

ion

.

A

Sidew

all t

o Uni

t (

Du

mur de

cфt

й а l

'appareil)

8”

(

203 mm

)

B

Top

of unit

to

an

unshi

elded

8”

(

203

m

m)

mant

le

(Le

sommet de

l'unité à

un

m

anteau

de chem

inée

non blindé)

8”

(203 m

m

)

C

U

nit

to top

facing (

prot

ruding ¾”

[19

m

m

])

(

De

l'uni

au

sommet

du

parement

)

8”

(203

m

m

)

D

U

nit

to side

faci

ng

(pr

ot

rudi

ng

¾

[19

m

m]

)

(D

e l'

unit

é

au

côté

du parement)

8”

(

203

m

m

)

E

From door

opening of unit t

o

edge of f

loor protect

ion

(

D

e

la por

te ouvrant au devant de prot

ec

tion de pl

ancher

)

6”

(

152 mm)

F

Fr

om

si

de of

unit to edge

of fl

oor

pr

ot

ecti

on

(De

l'ouverture

d

e

porte

po

ur

pr

endre parti

de

pr

otecti

on de

plancher

)

6

” (

152

m

m

)

Combus

tible

flo

ors must

be pro

tec

ted by a

non-c

om

bu

st

ible material. -

See

Owner

s M

anu

al

.

Le planche

r combusti

ble doit

êt

re protégé par

un mat

ér

iel

incombusti

ble.

- Con

sult

ez le

manua

l.

IN

STALLED

AS

A

FI

REPLAC

E

INSER

T STO

VE M

ODE

L

(GFI55)

/ A

INSTALLE

COM

ME

UN

MO

DÈLE

SUR

PIE

D

D

E PO

ELE.

M

inim

um

cl

ear

ances

to com

bus

tibl

e mat

er

ials.

/ Les

dégagements

mini

mum

s

aux

m

at

ériels

com

bust

ibl

es:

A

S

id

ew

all t

o Uni

t (

Du

m

ur

de

cфt

й а l

'appareil)

6” (152

m

m)

B

Backwal

l to U

nit

(Du

m

ur

de

der

rière à

l'a

pp

areil

)

3” (76 m

m

)

C

C

orner

to

Uni

t (

D

u coi

n

à l

'appareil

)

2”

(

51

mm)

D

Wal

l to vent

(Le

m

ur

pour

donner

ven

t)

3”

(76

m

m

)

E

Fr

om

door openi

ng of

uni

t to edge of floor

protect

ion

(

D

e l

a

porte

ouvr

ant

au devant de protection de pl

ancher)

6”

(

152 mm

)

N

OTE:

A

com

bu

stibl

e f

loor

must be protect

ed

by a

non-

combustible mater

ial

- Width 27" (686mm

) by

depth 34"

(864mm

). (Un plancher combus

tibl

e doi

t etre protege

par

un

mater

iel i

ncom

bustible.

La largeur

27"

(686 m

m) par l

a

profondeur 34" (864mm

).

)

M

ini

mum

Al

co

ve Width (La largeur

m

inim

um de l

'alcove)

36

(9

14 mm

)

Mini

mum

Al

cove

Hei

ght (

La hauteur mini

m

um de l

'alcove)

48

” (

1219 mm)

M

axi

m

um Al

cov

e Depth (La profondeur m

axim

um

de

l'alcove)

30

” (

762

mm)

IN

STALLED

AS A

FRE

ESTAND

ING

STO

VE

M

ODE

L

(GF55)

/ A

INSTA

LLE

CO

MM

E

U

N

M

O

DÈLE

FS,

QU’

IL

SOI

T EN

CASTRÈ,

S

UR

PIED

OU

DA

NS

U

NE

M

AI

SON

MO

BI

LE.

Mi

nimum

clearan

ces t

o combusti

ble

materials.

/ L

es

gagement

s mi

nimum

s

aux mat

ér

ie

ls

combusti

bl

es:

Ser

ial

No.

/

No.

De Serié:

Greenfire

GF55 (Stove)

GFI55 (Insert)

M

odel

/ Modèl

e:

15

956

B

A

D

C

Adjacent

wall

F

E

Fl

oor

Pr

ot

ecti

on

A

B

C

E

Bac

kwall

Sidew

all

D

Pou

r dém

arrer

le

poêl

e:

Appuyer sur le bouton "ON

/OFF".

Si le

Auger n

écessite d'

être amorcé, appuyer sur le

bouton m

anuel d'al

imentation

du Auger

jusqu'à ce que

le

s granules se d

éver

sent da

ns le

pot de combusti

on.

Pour faire fonctionner le poêle :

MODE

MANU

EL

: Lors

que l

e feu e

st bien ét

abli, les réglages

peuvent

être aj

ust

és

. /

MODE "HIG

H/LOW" : (

N

écessite

un thermost

at)

Lorsque le

therm

ostat

requière de l

a

chal

eur

, les r

églages p

euvent être ajustés. Lorsque l

es contacts du

therm

ostat ouvrent

, l

e régl

age du

ni

veau

de chaleu

r et

les venti

lateurs s'a

juster

ont au

réglage " bas " jusqu'à ce que les

contacts du therm

ostat se

refer

ment. / M

ODE "AUT

O/OFF" : (

N

écessite un the

rmostat) Lorsque les contacts du th

er

most

at

ferm

ent, le

poêle s'

all

um

era

aut

om

atique

m

ent.

Lorsque l

a tempér

ature adéqu

ate est att

ein

te, l

es réglag

es peuvent être aj

ustés. Lo

rsque les conta

cts du

ther

mostat ouvr

ent,

le poêl

e s'

ajustera aux r

églages "

LOW"

pendant 30

minutes.

Si

le

s cont

act

s du therm

ostat sont fer

més pendant

ces 30

m

inut

es, l

e réglage de

ni

veau de chale

ur

r

etournera

en r

ég

lages "

MAN

UEL" ou

si les contact

s du thermostat restent ou

ve

rts, le poêle entamera le pr

ocessus d'arrêt.

P

our

ét

eindre l

e poê

le : M

ODE MANU

EL

E

T "

H

IGH/LOW "

: Appuyer

sur

le bouton "ON

/OFF".

MODE

"AU

T

O

/ OFF

" : Régl

er l

e ther

mostat à l

a bai

sse

ou

éteignez le.

Manu

fa

ctur

ed

in

Ca

nad

a

for

/

F

abr

iqué

da

ns

le

Cana

da

pou

r:

FPI

Fir

epl

ac

e

Pr

oduc

ts I

nt

er

nati

onal

Ltd.

Delta,

BC,

Cana

da

M

odel

B

IH Onl

y Mini

mum

C

learance to C

om

bustibl

e Material

s / Espace de

dégagem

ent requi

s pour l

e modèle BIH

:

G

B

H

BIH

Model

E

FP

I o

r BIH

M

odels

G

Fr

om

S

ides and rear

wal

ls to standof

fs

(

Les murs

côté et

mur

d'arrière à spacer

s)

0” (0 mm

)

H

Recess de

pth

(

Le dos de poêl

e à

une pr

ofondeur

)

11”

(

280

mm)

FS Model

GF55-081a



This manual is related to the following products: