beautypg.com

Maintenance, Maintenance of gold-plated doors, Door gasket – Regency Classic I2400 Medium Wood Insert User Manual

Page 15: Door latch adjustment, Glass cleaning, Glass replacement, Glass removal

background image

Regency I2400M

15

Maintenance

Maintenance of

Gold-plated doors

The gold electroplated finish on the doors requires

little maintenance, and need only be cleaned with

a damp cloth. DO NOT use abrasive materials or

chemical cleaners, as they may harm the finish

and void the warranty.

door GasKet

If the door gasket requires replacement, 7/8"

diameter material must be used. A proper high

temperature gasket adhesive is required. A gasket

repair kit, Part # 846-570 is available from your

local Regency dealer.

door latcH

adjustMent

The door latch may require adjustment as the

door gasket material compresses after a few

fires. Removal of the spacer washer, shown in the

diagram below, will allow the latch to be moved

closer to the door frame, causing a tighter seal.

Remove and replace the nuts, washer as shown.

Glass cleaninG

Only clean your glass window when it is cool.

Your local retailer can supply you with special

glass cleaner if plain water and a soft cloth does

not remove all deposits.

Glass replaceMent

Your Regency Insert is supplied with 5 mm.

Neoceram ceramic glass (Part #846-304) that

will withstand the highest heat that your unit will

produce. In the event that you break your glass

by impact - purchase your replacement from an

authorized Regency dealer only, and follow our

step-by-step instructions.

avoid impact on glass doors such

as striking or slamming shut.

Glass reMoVal

Allow the stove to cool before removing or replacing

glass. Remove the door from the insert and remove

the glass retainer. Use caution when removing

broken glass to prevent injury.

When placing the replacement glass in the door,

make sure that the glass gasketing will properly seal

your unit. Replace the retainer and tighten securely,

but do not wrench down on the glass as this may

cause breakage. Do not substitute materials. If your

glass door does break, do not continue to use your

unit until it has been replaced.

annual maintenance

Completely clean out entire unit

Annually

Inspect air tubes, baffles and bricks

Replace any damaged parts.

Adjust door catch / latch

If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust latch after new gasket installed.

Inspect condition and seal of:
Glass Gasket
Door Gasket

Perform paper test - replace gasket if required

Paper Test

Test the seal on the loading door with a paper bill.
Place a paper bill in the gasketed area of the door on a cold stove–close
the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch,
if that doesn't solve the problem replace the door gasket.

Check and lubricate door hinge + latch

Use only high temperature anti seize lube. (ie. never seize)

Check glass for cracks

Replace if required.

Clean blower motor

Disconnect power supply.
Remove and clean blower.
*Do not lubricate*

Inspect and clean chimney

Annual professional chimney cleaning recommended.