Page 25: Fan maintenance

background image

Regency CI1200 / CI1250 Wood Cast Insert

25

MAINTENANCE

HANDLE

REPLACEMENT

1) Remove handle by undoing the hex head bolt using a 7/16" socket wrench.

2) Fit new door handle over door latch and secure.

Assemble handle by:

a) Placing lock washer and split lock washer over hex head bolt.

b) Place hex head bolt into handle.

c) Place spacer over hex head bolt threads.

d) Screw handle into door latch.

Spacer washers

DOOR CATCH

ADJUSTMENT

The door catch may require adjustment as the door gasket material compresses
after a few fi res. Removal of the spacer washer, shown in the diagram below,
will allow the catch to be moved closer to the door frame, causing a tighter
seal. Remove and replace the nuts, washer and spacer as shown.

TO REMOVE THE FAN

1) See next page.

Maintenance: The sealed bearings are lubricated, there is no need to
lubricate them further. (Extra lubricant will cause more lint and dust buildup
- causing the bearings to prematurely fail).
Regular cleaning and vacuuming of the fan area will add to the life of the
motor.

IMPORTANT:
These fans collect a lot of dust from within your home. Ensure you
maintain these fan motors on a regular basis by vacuuming
the fan blades and housing using a soft brush nozzle.