6) Install the unit by fi rst setting the rear of the unit into the fi replace. See
diagram 3. Ensure that the unit is centered in the existing fi replace
and lined up with the fl ue adaptor.
7) Slide the unit back until the fl ue adaptor is slightly engaged.
8) At this point it is recommended to level the unit and ensure that the leveling
bolts rest on the surface of the fi replace. This will keep the adaptor from
binding as the unit is slid into position.
9) Insert the provided pull rod through the hole in the top center of the unit.
Secure the threaded end into the fl ue adaptor as shown in diagram 4. While
sliding the unit into place pull on the rod to ensure that the fl ue adaptor is
properly engaged. See diagram 5.
Pull Rod
10) Ensure that the unit is still level.
11) To complete the installation and to ensure a secure fi t and connection of
the fl ue adaptor to the insert, it is essential that the two bolts, fl at wash-
ers and lock washers (supplied with packaged manual) be installed and
tightened using a 1/2" socket as shown in diagram 6. This prevents the
possibility of creosote drip and exhaust gas leakage.
12) Remove the pull rod from the top center of the fi replace. See diagram 7.
NOTE: The pull rod should not be thrown away. It should be kept if
the stove is ever needed to be removed from the fi replace.