Summit SWC1966 User Manual
Page 19
19
The door will
not close
properly.
• The appliance is not properly level.
• The door was reversed and not properly
installed.
• The gasket is dirty.
• The shelves are out of position.
• Level the appliance with the
adjustable feet.
• Check the door hinge and reassemble
correctly.
• Clean the door gasket.
• Check the shelves and refit correctly.
Display “E0”,
“E1”. “E2”,
“E3”, “E4”,
“E5” or “E7”.
• “E0” indicates a communication error for
3-zone models.
• “E1” or “E2” indicates that the air
temperature sensor has failed.
• “E3” or “E4”indicates that the defrost
sensor in the evaporator has failed.
• “E5” indicates defrost heater failure.
• “E7” indicates door switch failure.
• Call for service.
The alarm
sounds and
the
temperature
display
flashes.
Has the appliance door been open for
longer than 60 seconds? If not, then the
temperature has risen higher or fallen
lower than the temperature that has been
set. This could be due to:
• The appliance door being opened too
often.
• The ventilation opening being covered
or too dusty.
• A lengthy interruption to the power
supply.
• A large number of bottles has been
added to the unit.
If yes, close the door.
• Do not open the door more often than
necessary.
• Clear the obstructions and remove the
dust.
• Leave the appliance to work for a
while until the set temperature has
been reached.
The icon “--”
is lit up and
flashing in the
temperature
display.
• The display temperature is out of range. • Only temperatures within the range
0~99°F/-9~37°C can be displayed. If
the temperature is not within this
range, the icon “--” will be displayed
instead. This is normal.