Scan Tech HFW Power Generator User Manual
Scan Tech Equipment
Scan Tech AS
Finnestadsvingen 23
Po.Box. 738
Tel.
+47 51 54 54 00
4029 Stavanger 4001 Stavanger Fax +47 51 54 54 50 www.scan-tech.no
Model
Engine
Power
kVA kW
P.R.P(1)S.By(2)P.R.P(1) S.By(2)
Gov.
(3)
Cyl
Feed.
(4)
Dimensions mm.**
L W H
Weight**
Kg
Fuel
Tank Ltr
Fuel Cons.*
L/h.
HFW‐60 T5
NEF45 SM 1A
60
63
48
50
M
4L
TC
2 750
1 100
1 500
1 525
175
13,7
HFW‐75 T5
NEF45 SM 2A
73
80
58
64
M
4L
TC
2 750
1 100
1 500
1 550
175
17,1
HFW‐100 T5
NEF45 TM 2A
100
108
80
86
M
4L
TCA
2 750
1 100
1 500
1 670
175
22,0
HFW‐135 T5
NEF67 TM 2A
130
143
104
114
M
6L
TCA
3 300
1 200
1 800
2 295
245
29,0
HFW‐160 T5
NEF67 TM 3A
160
175
128
140
M
6L
TCA
3 300
1 200
1 800
2 365
245
36,0
HFW‐180 T5
NEF67 TE 2A
180
194
144
155
E
6L
TCA
3 300
1 200
1 800
2 390
245
‐
HFW‐200 T5
NEF67 TE 2A
200
220
160
176
E
6L
TCA
3 300
1 200
1 800
2 435
245
41,3
HFW‐250 T5
C87 TE 1D
250
275
200
220
E
6L
TCA
3 800
1 400
2 105
3 840
445
‐
HFW‐305 T5
C10 TE 1D
300
330
240
264
E
6L
TCA
4 100
1 600
2 210
4 135
590
‐
HFW‐350 T5
C13 TE 2S
350
390
280
312
E
6L
TCA
4 100
1 600
2 210
4 295
590
‐
HFW‐400 T5
C13 TE 3S
400
440
320
352
E
6L
TCA
4 100
1 600
2 210
4 480
590
‐
*Fuel consumption measured in ltr/hr. at 100% load at 1500 rpm at 50Hz.
**Weights and dimensions are subject to variations depending to the
generators configuration solicited by the customer.
To be consulted by Scan Tech.
Ambient reference conditions:
1 000 mbar, 25°C, 30% relative humidity. Rating according to ISO 3046
1 – P.R.P. Prime Power – ISO 8528: Prime power is the maximum power
available during a variable power sequence, which may be run
for an unlimited number of hours per year, between stated maintenance
intervals.The permissible average power output during a 24 hours period
shall not exceed 80% of the prime power.10% overload available for
governing purposes only.
2 – Standby power (ISO 3046 Fuel Stop power): Power available for use at variable loads for limited annual
time (500h), within the following limits of maximum operatingtime: 100% loads 25h per year – 90% loads
200h per year. No overload available.
Applicable in case of failure of the main in areas of reliable electrical network.
3 – M= Mechanical speed governor.
E= Electronic speed governor.
4 – TC = Turbocharged; TCA = Turbocharged and aftercooled.
Scan Tech reserve the right of modify any characteristic without prior notice. Weights and dimensions based on products standards and sec / illustrations may include optional equipment.
Technical data here described correspond with the available information of the moment of printing. Industrial design under patent.