3— recommended tube diameters, Check-flo-rater® piston, Charging subcooling (txv-type expansion device*) – Bryant DELUXE 11 SEER R-410A User Manual
Page 3
—3—
RECOMMENDED TUBE DIAMETERS
* For tube sets greater than 50 ft, consult Application Guideline and Service Manual—Air Conditioners and Heat Pumps Using Puron® Refrigerant.
CHECK-FLO-RATER® PISTON
* Piston listed is for any approved non-capillary tube coil combination. Piston is shipped
with outdoor unit and must be installed in an approved indoor coil.
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*)
* Must be a Puron® approved hard shutoff TXV.
UNIT
SIZE
Liquid Tube Diameter (In.)
Vapor Tube Diameter (In.)
0 to 50 Ft
Tube Length
Long-Line Applications*
0 to 50 Ft
Tube Length
Long-Line Applications*
(Maximum Diameter)
018
3/8
3/8
5/8
3/4
024
5/8
3/4
030, 036
3/4
7/8
042, 048
7/8
1-1/8
060
1-1/8
1-1/8
UNIT SIZE–SERIES
PISTON*
IDENTIFICATION NO.
018-A
49
024-A
59
030-A
63
036-A
67
042-A
73
048-A
78
060-A
90
UNIT SIZE–SERIES
REQUIRED SUBCOOLING (°F)
018-A
15
024-A
15
030-A
16
036-A
18
042-A
18
048-A
16
060-A
14
M
A
N
U
F
A
C
T
U
R
E
R
CE
RT
IFIED
TO ARI
AS
C
O
M
P
L
Y
IN
G
W
IT
H
A
RI
STANDARD
21
0
U
N
IT
A
R
Y
AIR
CO
N
D
IT
IO
N
IN
G
EQUIPMENT
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.