Description, Housing – RKI Instruments 35-3000RK-LEL/O User Manual
Page 6
![background image](/manuals/571413/6/background.png)
2 • 35-3000RK-LEL/O Sample-Draw Detector
Description
This section describes the components of the sample-draw detector. The sample-draw
detector consists of the housing, flow system, and detection system.
Figure 1: Sample-Draw Detector Component Location
Housing
The sample-draw detector’s fiberglass housing is weather- and corrosion-resistant. It is
suitable for installation where general purpose equipment is in use.
The housing door is hinged on the left side and is secured by two latches on the right side.
The flowmeter and status lights are visible through a window in the housing door.
Four mounting feet are attached to the back of the housing (one at each corner). Use the
mounting feet to install the housing to a vertical surface. Use the two conduit hubs on the
bottom of the housing to make wiring connections to a gas monitoring controller.
An aluminum subpanel is mounted to the interior of the housing. The sample-draw
detector’s internal components are mounted to the subpanel.
Flow Alarm Setpoint
Adjustment Screw.
Detector Terminal
Strip
Exhaust
Fitting
Inlet
Fitting
Combustible
Gas
Detector
3/4" Conduit Hub,
2X
External
Wiring
Terminal
Strip
Hydrophobic
Filter
Bypass Valve
Flowmeter
Pilot LED
Fail LED
Flow Adjust
Potentiometer
Pump/Flow Switch
Terminal Block
Oxygen
Detector
Mounting
Foot, 4X