Specifications – RKI Instruments Beacon 200 RIg Monitor, H2S/H2S User Manual
Page 8

3 • Beacon 200 Rig Monitor Operator’s Manual
Specifications
Table 1 lists specifications for the Beacon 200 Rig Monitor.
WARNING: When using the Beacon 200 Rig Monitor, you must follow
the instructions and warnings in this manual to assure
proper and safe operation of the Beacon 200 Rig Monitor
and to minimize the risk of personal injury. Be sure to
maintain and periodically calibrate the Beacon 200 Rig
Monitor as described in this manual.
Table 1: Beacon 200 Rig Monitor Specifications
Description
Specification
Input Power
10.8 - 14.5 VDC, 1.2A VDC
Construction (housing)
Fiberglass/polyester with lexan window (NEMA 4X)
Controller Dimensions
21.0 in. H x 8.5 in. W x 7.00 in. D
(533 mm H x 216 mm W x 178 mm D)
Weight
20 lbs.
Environmental Conditions
•
-20°C to 50°C (-4°F to 122°F) max. ambient
•
Maximum humidity of 80% relative
Relays
•
Relay contacts rated for 10A @ 115/220V~ resistive or10A @ 30V
resistive
•
SPDT Form C
User Controls
•
Reset switch
•
Program buttons: ESCAPE, UP/YES, DOWN/NO, and ENTER
Detection Range
0 to 100 PPM (parts per million) H
2
S
Response Time
90% in 30 seconds
Accuracy
± 5% of reading or ± 2 ppm H
2
S (whichever is greater)