beautypg.com

Alarms – RKI Instruments GX-86 User Manual

Page 11

background image

Model GX-86 Instruction Manual

Operation • 7

Alarms

This section describes the GX-86’s gas alarms. Table 3 lists the low and high alarm levels
for each channel.

Combustibles (%LEL)

If the target combustible gas exceeds the first alarm setting (10% LEL for most
applications), a pulsed tone sounds and the COMB LED flashes.

If the target combustible gas rises above the second alarm setting (50% LEL for most
applications), the alarm tone and LED are continuous.

If the reading is above the detection range of the combustibles sensor (100% LEL), a
steady alarm sounds and the combustible gas reading is replaced by

OVER

.

Oxygen

If the oxygen content of the air drops below 19.5%, a pulsed tone sounds and the OXY
LED flashes.

If the oxygen content of the air rises above 23.5%, a steady alarm tone sounds and the
OXY LED remains on.

If the reading is above the detection range of the oxygen sensor (40.0%), a steady
alarm sounds and the oxygen reading is replaced by

OVER

.

H

2

S

If the H

2

S reading exceeds the first alarm setting (10.0 ppm for most applications), a

pulsed tone sounds and the H

2

S LED flashes.

If the H

2

S reading rises above the second alarm setting (30.0 ppm for most

applications), the alarm tone and LED are continuous.

If the H

2

S reading is above the detection range of the H

2

S sensor (100 PPM), a steady

alarm sounds and the H

2

S reading is replaced by

OVER

.

CO

If the CO reading exceeds the first alarm setting (25 ppm for most applications), a
pulsed tone sounds and the CO LED flashes.

If the CO reading rises above the second alarm setting (100 ppm for most
applications), the alarm tone and LED are continuous.

If the CO reading is above the detection range of the CO sensor (300 PPM), a steady
alarm sounds and the CO reading is replaced by

OVER

.

Table 3: GX-86 Alarm Levels

Channel

Low

High

LEL

10% LEL

50% LEL

O

2

19.5% O

2

23.5% O

2

H

2

S

10.0 ppm

30.0 ppm

CO

25 ppm

100 ppm