6. WIRING DIAGRAM

WARNING

Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source.

!

Field wiring

remote control

(see notes 3 & 4)

120 V,

60 Hz

W1

J5

J7

J6

J4

ELECTRONIC

ASSEMBLY

1 2 3

1

2

1

2

1 2 3

1

2

3

4

1 2

1 2 3 4 5

1

2

3

4

5

J8

J9

J11

J10

1
2

J12

J13

J14

10

9 8 7 6 5 4 3 2 1

B

24 V

class

2

9.5 V

class 2

120V, 60Hz

Neutral

120 V,

60Hz

Line

CPU

K2

K4

K5

J5-2

J10-1

J10-2

Line voltage factory wiring

Class 2 low voltage factory wiring

Class 2 low voltage field wiring

See note 1

120 V

90 V

68 V

neutral

Door interlock

s

w

it

c

h

(magnetically

a

ct

u

a

te

d

Exhaust fan

motor

1

2

3

4

5 1

2

1 2

J3

J2

J1

Damper motor

BK

Override

switch

Furnace blower interlock

J14-1 : NO

J14-2 : COM

J14-3 : nc

(optional; see notes 3, 5)

DAMPER

ELECTRONI

C ASSEMBLY

Defrost

temperature

sensor

WIRING DIAGRAM

LOGIC DIAGRAM

Exhaust fan motor

Supply fan motor

J5-1

J5-3

J7-2

J7-1

J4-1

J4-3

J6-2

J6-1

K1

K3

K2

24 V

class

2

9.5 V

class 2

120 V

90 V

68 V

neutral

J9-1

J9-2

J9-3

J4-2

J9-4

Exhaust fan motor

capacitor

Supply fan motor

capacitor

J8-1

J8-2

J8-4

J8-5

K4

J12-2

J12-1

A1

Damper motor

J3-2

J3-1

J2-2

J2-1

F1

J12-5

J12-4

J12-3

J2-3

J2-4

J2-5

Door interlock switch

J11-2

J11-1

K1

K3

K5

J14-3

J14-1

J14-2

Furnace

blower

interlock

(optional; see

notes 3, 5)

J14-4

J14-5

J14-6

J14-7

J14-8

J14-9

J14-10

Override

switch

(optional; see

notes 3, 4)

Field wiring

remote

c

o

n

tr

o

l (see

notes 3, 4)

ICP

nc

BK

Y

R

G

W

W

BK

W

BL

R

G

BK

BL

BN

BN

BK

BK

BK

BK

BK

BL

Exhaust fan

motor

capacitor

Supply fan

motor

capacitor

Supply fan

motor

G

G

BN

BN

Y

Y

BK

W

A2

A2

M3

T1

S1

R1

A1

F1

M1

C1

C2

M2

(optional; see

notes 3 & 4)

VE0130A

NOTES

1.

For continued fire protection. Use specified UL listed/CSA

Certified line fuse.

2. If any of the original wire, as supplied, must be replaced,

use the same equivalent wire.

3. Field wiring must comply with applicable codes,

ordinances and regulations.

4. Remote controls (class 2 circuit) available,

see instruction manual.

COLOR CODE

BK BLACK

BL

B

L

U

E

BN BROWN

G GREEN

R RED

W

WHITE

Y YELLOW nc no

connection

5. Furnace fan circuit must be class 2 circuit only.

Critical characteristic.

6. To obtain medium speed, interchange

BLUE and RED transformer wires at J9.

The medium speed is for special use only.

See note 6

reed switch)

- 20 -