Controls, Cont’d) 4.2.1 e, Vt4w m – Broan HRV90H User Manual
Page 18: 3 vt4w o

4. CONTROLS
(CONT’D)
4.2.1 E
LECTRICAL
C
ONNECTION TO
VT4W M
AIN
W
ALL
C
ONTROL
NO C NC I OC OL Y R G B
B
G
OC
MAIN WALL CONTROL
LITE-TOUCH BRONZE
and
SIMPLE TOUCH BRONZE
REAR VIEW
G B
Y
VE0101A
M
AIN WALL
CONTROL
VT4W
REAR VIEW
4.2 E
LECTRICAL
C
ONNECTION TO
O
PTIONAL
W
ALL
C
ONTROLS
(
CONT
’
D
)
4.2.2 E
LECTRICAL
C
ONNECTION TO
O
PTIONAL
A
UXILIARY
W
ALL
C
ONTROLS
NOTE:
If another optional auxiliary wall control
is activated when the Humidity Control
is installed, this control will override
the Humidity Control commands.
NO C NC I O C OL Y R G B
20-MINUTED LIGHTED PUSH BUTTON
(5 MAXIMUM)
60-MINUTE
CRANK TIMER
HUMIDITY CONTROL
VE0110A
COM
FOR T ZO
N E
O
FF
%
REL
ATIVE HUMIDIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY
CONTROL
Once the wall control(s) connections have been made, insert the terminal connector in the bottom of the unit, on the electrical
compartment front face.
4.3 VT4W O
PTIONAL
M
AIN
W
ALL
C
ONTROL
O
PERATION
WARNING
Risk of electric shock. Before performing
any maintenance or servicing, always
disconnect the unit from its power source.
AVERTISSEMENT
Danger d’électrocution. Débranchez
toujours l’appareil avant d’entreprendre
des travaux d’entretien ou de réparation.
CAUTION
Unscrew both screws to open the electrical
compartment. To completely remove, detach
from its retention wire inside.
ATTENTION
Dévisser les deux vis pour ouvrir le compartiment
électrique. Pour retirer complètement, le
détacher de son fil de rétention intérieur.
No light OFF or remote controled
Amber light LOW speed
Green ligh HIGH speed
Blinking light See User Manual
Sans lumière Arrêté ou contrôlé
par contrôle mural
Lumière ambre Basse vitesse
Lumière verte Haute vitesse
Clignotant Voir guide d’utilisation
VD0182
TERMINAL
CONNECTOR
INTERMITTENT
MAX
MIN
VC0070
VT4W
C
OLOR
M
ODE
S
UGGESTED
U
SE
G
REEN
I
NTERMITTENT
S
ELECT THIS MODE WHEN YOU ARE AWAY FROM THE HOUSE
FOR A FEW DAYS
. A
LSO
,
WHEN YOU DEEM THE INSIDE AIR IS
TOO DRY IN HEATING SEASON
,
OR TOO HUMID DURING
COOLING SEASON
. I
N THIS MODE
,
THE UNIT IS
OFF
FOR
40
MINUTES PER HOUR AND VENTILATES AT MINIMUM SPEED
THE REMAINING
20
MINUTES OF THE HOUR
.
Y
ELLOW
M
IN
S
PEED
F
OR NORMAL DAILY OPERATION
.
V
ENTILATION
R
ED
M
AX
S
PEED
F
OR EXCESS POLLUTANTS AND
H
UMIDITY
V
ENTILATION
(
PARTIES
,
ODORS
,
SMOKE
,
ETC
.).
- 18 -