Operating the machine, 16 replacing the machine fuses – Retsch PT 200 User Manual
Page 27

Operating the machine
27
X = 39.75 mm opening width
The accuracyof this calculation depends on the maximum particle size. The finer
the feed quantity, the more precise the calculation.
Determine the minimum opening width.
The minimum opening width must correspond to at least three times the maximum
particle size .
Example :
Particle size = 8 mm
Minimum opening width= 3 x 8 = 24 mm
Formula:
X
min
= 3 x d
max
If the opening width is narrower, a distortion of the sub-sample can be expected.
5.15.2 Determining the minimum opening width
The minimum opening width must correspond to at least three times the maximum
particle size.
Example :
Particle size = 8 mm
Minimum opening width= 3 x 8 = 24 mm
Formula:
X
min
= 3 x d
max
If the opening width is narrower, a distortion of the sub-sample can be expected in
this case.
Pos : 6.37 /00005 Ü berschriften/1.1 Ü bersc hriften/1.1 Übersc hriften BD A/11 Austausc h der Ger ätesic her ung @ 0\mod_1227260127023_9.doc @ 3952 @ @ 1
5.16 Replacing the machine fuses
Pos : 6.38 /00010 Bedi enungsanleitung en Kapitels ammlungen/PT200 (2011)/0015 PT 200 Bedienung/1560 PT200 M odul Aus tausc h der Ger ätesic herung @ 3\mod_1302848894412_9.doc @ 25196 @ @ 1
Fig. 16: Fuse holder
Fuses required:
2 glass fuses T 0.315 A (5x20mm)
•
Pull the mains plug.
•
Pull out the fuse holder (B).
•
Replace the fuses.
•
Insert the fuse holder.
B