6 cleaning and service, Cleaning and service, Warning – Retsch GM 200 User Manual
Page 31
![background image](/manuals/571083/31/background.png)
Cleaning and service
31
This overload protection switch disconnects the device from the power supply if the
machine is overloaded.
•
After allowing the device to cool down it can be used with the power supply
again by pressing the overload protection switch (K).
Fig. 14: Overload protection switch
Pos : 9. 1 / 00005 Übersc hrift en/1. Übersc hrift en/1 Rei nigung und Wart ung @ 0\ mod_1231167007723_9.doc @ 5450 @ @ 1
6 Cleaning and service
Pos : 9. 2 / 00004 War nhi nweis e/ W0003 WARN UNG R einig ung Stromstoß neu @ 1\ mod_1236239978437_9. doc @ 7686 @ @ 1
WARNING
Risk of a fatal electric shock
-
An electric shock can cause injuries in the form of burns and cardiac
arrhythmia, respiratory arrest or cardiac arrest.
• Do not clean the blender under running water. Use only a cloth dampened
with water.
• Disconnect the power supply plug before cleaning the blender.
Pos : 9. 3 / 00010 Bedienungsanlei tungen Kapit elsamml ung en/GM 200 ( 2010)/0025 GM200N R einigung und Wartung/ 2505 Modul Bec her aufna hme reinig en @ 4\ mod_1335509265798_9. doc @ 27606 @ @ 1
Fig. 15: Cleaning the jar support
NOTE
Sample material may get underneath the jar support (Db) where the jar support (D)
frequently gets very dirty as a result of liquid or greasy samples.
•
Where necessary also clean the area underneath the jar support (Db).
Material may otherwise, under unfavourable circumstances, get inside the device.
D
Db
K