beautypg.com

Bnc 75ω – Northern Connectors Radiall BNC Series Coaxial Connectors User Manual

Page 28

background image

10-28

BNC 75Ω

BULKHEAD JACKS AND RECEPTACLES

STRAIGHT BULKHEAD JACKS CRImP TYPE fOR fLEXIBLE CABLES

RECEPTACLES WITH SOLDER POT

Fig. 1

Fig. 2

Cable group

Cable group

dia.

Part number Fig.

Dimensions (mm) Captive center

contact

Panel

drilling

Note

A

B

C

RG179

2.6/75/S

R142 306 500

1

26

2.95 0.4

yes

P18

Reverse crimping/Commercial version

R142A 306 500

no

Reverse crimping/ECO version

R142 306 503

yes

Reverse crimping

R142 331 011

2

38

1.75

0.4

P14 or P20

Panel sealed/Silver plated

BT3002

3.6/75/D

R142A 325 106

2

36

2.1

0.5

no

P14 or P20

Panel sealed/ECO version

RG59/RG62

6/75/S

R142 334 161

2

35

6.6 0.75

yes

P14 or P20

Panel sealed/Commercial version

RG59/RG62

6/75/S

R142A 334 161

2

35

3.8

0.7

P14 or P20

Panel sealed/ECO version

Fig. 1

Fig. 3

Fig. 2

Part number

Fig.

Captive center contact

Panel drilling

Flange holes A

Note

R142 412 000

1

yes

P07

4 x M2.5

Square flange + unit packaging

R142 562 000

2

P18

Bulkhead female receptacle

unit packaging

R142 580 000

3

P18

Bulkhead male receptacle

panel sealed + unit packaging

For others types of cables (75Ω, 93Ω or BT cables), please see "additional connectors" on page 10-32.

To download data sheets and assembly instructions, visit www.radiall.com & enter the part number in the Search box.

Bold

part numbers represent products typically in stock & available for immediate shipment.

See page 8 and 9 for packaging information.