beautypg.com

Hsk-emc-ex-e cable glands, Rohs, Hsk-m-emv-ex metr – Northern Connectors Hummel Cable Glands - EMC-Ex-e for Hazardous Areas User Manual

Page 4

background image

126

AG

H

GL

M 12 x 1,5

3 – 6,5

6,5

19

14

1.616.1200.50

1.646.1200.50

M 12 x 1,5

2 – 5

6,5

19

14

1.616.1200.51

1.646.1200.51

M 16 x 1,5

6 – 10

6

22

20

1.616.1600.50

1.646.1600.50

M 16 x 1,5

3 – 7

6

22

20

1.616.1600.51

1.646.1600.51

M 20 x 1,5

10 – 14

6

23

24

1.616.2000.50

1.646.2000.50

M 20 x 1,5

7 – 12

6

23

24

1.616.2000.51

1.646.2000.51

M 25 x 1,5

14 – 18

7

24

30

1.616.2500.50

1.646.2500.50

M 25 x 1,5

10 – 16

7

24

30

1.616.2500.51

1.646.2500.51

M 32 x 1,5

20 – 25

8

31

40

1.616.3200.50

1.646.3200.50

M 32 x 1,5

13 – 20

8

31

40

1.616.3200.51

1.646.3200.51

M 40 x 1,5

22 – 32

8

37

50

1.616.4000.50

1.646.4000.50

M 40 x 1,5

20 – 26

8

37

50

1.616.4000.51

1.646.4000.51

M 50 x 1,5

32 – 38

9

37

57

1.616.5000.50

1.646.5000.50

M 50 x 1,5

25 – 31

9

37

57

1.616.5000.51

1.646.5000.51

M 63 x 1,5

37 – 44

10

38

64 / 68

1.616.6300.50

1.646.6300.50

M 63 x 1,5

29 – 35

10

38

64 / 68

1.616.6300.51

1.646.6300.51

EN

50262

RoHS

II 2G 1D

Operating Temperature - 20°C – 95 °C (- 4°F – 203°F)/

- 60°C – 95 °C (- 76°F – 203°F)

Accessories see page 73 and 143

HSK-EMC-Ex-e cable glands

HSK-M-EMV-Ex

Metr.

Number Number

AG GL H

HSK-M-EMV-Ex HSK-M-EMV-Ex

mm mm mm mm

- 20 °C – 95 °C - 60 °C – 95 °C

(- 4 °F – 203 °F) (- 76 °F – 203 °F)

Protection IP 68 – 10 bar / IP 69K (NEMA 6 – 150 PSIG)

within the specified clamping range

O-Ring Buna-N

Seal Buna-N

Clamping insert Polyamide

Material Nickel plated brass

Dimensions and specifications may be changed without prior notice

For the international certificates
please see page 176 or our homepage
www.hummel.com

See our homepage www.hummel.com
for assembling advices for maximum
cable diameters

Advice:
- Elongated threads on request
- Stainless steel on request