14

05

har

-flex

1

5

X

X

X

X

X

X

X

X

X

X

X

X

Technical characteristics

Working voltage acc. to IEC 60 664-1

The working voltage depends on user specific operational
conditions. Depending on the installation category, the degree
of pollution and the entire electrical environment, the working
voltage is different. The standard IEC 60 664-1 specifies, in
general, the minimum insulation distances for equipment. But it
can also be used to determine the maximum working voltage with
given requirements.

The following table shows the most common conditions applicable
for the

har-flex

®

connectors and exemplary calculations for the

working voltage. For installation category, degree of pollution and
other requirements which are not shown in the table we refer to
the IEC 60 664-1.

Clearance / Creepage
distance

0.4 mm

CTI-Value

< 400

Isolation group

III a/b

Electrical field type

Case A

(Inhomogeneous field)

Case B

(Homogeneous field)

Installation category

I

II

I

II

Degree of pollution

1

1

1

1

Working voltage max.

150 V

100 V

150 V

150 V

Explanations:

– CTI value and isolation group are fixed values by the

har-flex

®

connector characteristics.

– Installation category I: Equipment is intended for use only in

appliances or installation parts, in which no overvoltages
can occur. Equipment in this installation category in normally
operated at extra low voltage.

Installation category II: Equipment is intended for use in
installations or parts of installations, in which lightning
overvoltages need not be considered. Overvoltages caused by
switching must be taken into account.

– Pollution degree 1: No pollution or only dry, non-conductive

pollution occurs. The pollution has no influence.

Pollution degree 2: Only non-conductive pollution occurs.
A temporary conductive caused by condensation must be
expected occasionally.

Part number definition

The

har-flex

®

part numbers have 14 digits and are based on the following scheme:

15

har-flex

®

family

Connector style

11

straight male connector

1.75 mm stacking height

12

straight male connector

3.25 mm stacking height

15

angled male connector

21

straight female connector

6.25 mm stacking height

22

straight female connector

9.05 mm stacking height

25

angled female connector

Number of contacts

Durability

2 performance

level 1

5 performance

level S4

6 performance

level 2

Termination

6 SMT termination

Counting number

Packaging

000 Tape and reel packaging

333 Samples