PAGE 16 — G-55H GASOLINE VIBRATOR — OPERATION & PARTS MANUAL — REV. #0 (03/07/06)

6. Grasp the

recoil starter grip (Figure 10) and slowly pull

it out. The resistance becomes the hardest at a certain
position, corresponding to the compression point. Pull
the starter grip briskly and smoothly for starting.

Figure 10. Starter Grip

3. Place the engine

choke lever (Figure 8) in the CLOSED

position if starting a

cold engine. Place the choke lever

in the OPEN position if starting a

warm engine or the

temperature is warm.

G-55H GASOLINE VIBRATOR — START-UP PROCEDURES

Starting the Engine

1. Place the engine

fuel valve lever (Figure 6) to the ON

position.

2. Place the engine

throttle lever (Figure 7) to the IDLE or

SLOW position.

Figure 6. Engine Fuel Valve Lever

Figure 7. Throttle Lever

Figure 8. Engine Choke Lever

5. Place the engine

ON/OFF switch (Figure 9) in the ON

position.

Figure 9. Engine ON/OFF Switch

This section is intended to assist the operator
with initial start-up. It is extremely important
that this section be read carefully before
attempting to use the vibrator in the field.

DO NOT use your vibrator until this section is thoroughly
understood.

Failure to understand the operation of this vibrator could
result in

severe damage to the vibrator or personal injury.

See Figures 2 and 3 for the location of any control
referenced in this manual.

WARNING

WARNING

WARNING

WARNING

WARNING

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

NEVER operate the vibrator in a
confined area or enclosed area structure
that does not provide ample

free flow

of air.

General Safety

Respiratory Hazard