G-55h gasoline vibrator — start-up procedures, Warning, Warning caution caution caution caution caution – Multiquip G55H User Manual
Page 16

PAGE 16 — G-55H GASOLINE VIBRATOR — OPERATION & PARTS MANUAL — REV. #0 (03/07/06)
6. Grasp the
recoil starter grip (Figure 10) and slowly pull
it out. The resistance becomes the hardest at a certain
position, corresponding to the compression point. Pull
the starter grip briskly and smoothly for starting.
Figure 10. Starter Grip
3. Place the engine
choke lever (Figure 8) in the CLOSED
position if starting a
cold engine. Place the choke lever
in the OPEN position if starting a
warm engine or the
temperature is warm.
G-55H GASOLINE VIBRATOR — START-UP PROCEDURES
Starting the Engine
1. Place the engine
fuel valve lever (Figure 6) to the ON
position.
2. Place the engine
throttle lever (Figure 7) to the IDLE or
SLOW position.
Figure 6. Engine Fuel Valve Lever
Figure 7. Throttle Lever
Figure 8. Engine Choke Lever
5. Place the engine
ON/OFF switch (Figure 9) in the ON
position.
Figure 9. Engine ON/OFF Switch
This section is intended to assist the operator
with initial start-up. It is extremely important
that this section be read carefully before
attempting to use the vibrator in the field.
DO NOT use your vibrator until this section is thoroughly
understood.
Failure to understand the operation of this vibrator could
result in
severe damage to the vibrator or personal injury.
See Figures 2 and 3 for the location of any control
referenced in this manual.
WARNING
WARNING
WARNING
WARNING
WARNING
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
NEVER operate the vibrator in a
confined area or enclosed area structure
that does not provide ample
free flow
of air.
General Safety
Respiratory Hazard