SCT SERIES WALK-BEHIND TROWEL — PARTS & OPERATION MANUAL — REV. #4 (04/02/07) — PAGE 19

SCT SERIES TROWEL — ASSEMBLY AND INSTALLATION

Figure 11. Cable Yoke Attachment

5.

Using a wrench, tighten the second brass set nut up against
the yoke boss. This will lock the cable in place.

6.

Use a wrench and finish tightening the first brass set nut up
against the yoke boss.

2.

Remove one brass set nut from the blade pitch cable end
as shown in (Figure 10).

3.

Thread the second brass set nut towards the cable as far
as possible.

4.

Insert the cable end through the yoke eyelet (Figure 11)
Tighten the first brass set nut by hand to remove all the
slack from the cable.

Figure 10. Blade Pitch Cable

Safety Stop Wire

Locate the

SAFETY STOP

wire protruding from the handle tube

(Figure 8) and connect it to the

tail wire on the engine. Test the

safety stop switch to insure proper operation.

Figure 8. Engine Safety Stop Wire Connection

Figure 9. "No Pitch" Position

1.

Expose the pitch cable to maximum by adjusting the handle
pitch to the "no pitch" position. On the standard model turn
the pitch control counter-clockwise, (Figure 9).

Pitch Cable Installation

YOKE

THREAD CABLE END

THROUGH YOKE EYELET

TIGHTEN SECOND

BRASS SET NUT

AGAINST YOKE BOSS

USE A WRENCH TO

TIGHTEN FIRST BRASS

SET NUT AGAINST YOKE BOSS