Epoxy/m series trowel— basic engine, Danger, Danger warning warning warning warning warning – Multiquip EPOXY/M SERIES User Manual
Page 20

PAGE 20 —EPOXY SERIES WALK-BEHIND TROWEL— OPERATION AND PARTS MANUAL — REV. #5 (10/06/10)
Figure 4. Engine Controls and Components
INITIAL SERVICING
The engine (Figure 4) must be checked for proper lubrication and
filled with fuel prior to operation. Refer to the manufacturers engine
manual for instructions & details of operation and servicing. The
engine shown above is a HONDA engine, operation for other
types of engines may vary somewhat.
1.
Fuel Filler Cap – Remove this cap to add unleaded
gasoline to the fuel tank. Make sure cap is tightened
securely. DO NOT over fill.
5.
Fuel Valve Lever – OPEN to let fuel flow, CLOSE to stop
the flow of fuel.
6.
Choke Lever – Used in the starting of a cold engine, or in
cold weather conditions. The choke enriches the fuel
mixture.
7.
Air Cleaner – Prevents dirt and other debris from entering
the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element.
8.
Spark Plug – Provides spark to the ignition system. Set
spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean
spark plug once a week.
9.
Muffler – Used to reduce noise and emissions.
10. Fuel Tank – Holds unleaded gasoline. For additional
information refer to engine owner's manual.
NOTE
Operating the engine without an air filter,
with a damaged air filter, or a filter in need of
replacement will allow dirt to enter the
engine, causing rapid engine wear.
EPOXY/M SERIES TROWEL— BASIC ENGINE
HONDA engine shown.
Adding fuel to the tank should be done only when
the engine is stopped and has had an opportunity
to cool down. In the event of a fuel spill, DO NOT
attempt to start the engine until the fuel residue has
been completely wiped up, and the area
surrounding the engine is dry.
2.
Throttle Lever – Used to adjust engine RPM speed (lever
advanced forward
SLOW
, lever back toward operator
FAST
).
3.
Engine ON/OFF Switch – ON position permits engine
starting, OFF position stops engine operations.
4.
Recoil Starter (pull rope) – Manual-starting method. Pull
the starter grip until resistance is felt, then pull briskly and
smoothly.
DANGER
DANGER
DANGER
DANGER
DANGER
WARNING
WARNING
WARNING
WARNING
WARNING
Engine components can generate extreme
heat. To prevent burns, DO NOT touch these
areas while the engine is running or
immediately after operating. NEVER operate
the engine with the muffler removed.