OperatiOn

sTaRTINg The eNgINe

1. With one foot on the ground and the other foot placed

on the trowel’s platform, grasp the grab handles lifting

yourself onto the trowel. Then sit down in the operator’s

seat.

2. This trowel is equipped with a Safety Bypass Switch.

The trowel will not move unless an operator is sitting in

the seat. While the engine can be started or continue

to run with the operator off the seat, the rotors will not

rotate. The weight of an operator activates a switch

within the seat allowing the rotors to turn.

WaRNINg

NeveR operate the trowel in a confined

area or enclosed area structure that does

not provide ample free flow of air.

cauTION

aLWays wear approved eye and hearing

protection before operating the ride-on

power trowel.

cauTION

NeveR place hands or feet inside the guard rings while

the engine is running.

aLWays shut the engine down

before performing any kind of maintenance service on

the trowel.

NOTICE

dO NOT grab hold of the joysticks to lift yourself onto

the trowel. Pulling on the joysticks repeatedly will

weaken the units.

aLWays use the grab handles to

lift yourself on the trowel.

WaRNINg

NeveR disable or disconnect the Safety Bypass

Switch. It is provided for the operator's safety. Injury

may result if it is disabled, disconnected or improperly

maintained.

3. Insert the ignition key into the ignition switch (Figure 11).

Figure 11. Ignition Switch and Key

4. Turn the ignition key clockwise to the

ON position. Aux

1, Aux 2, Coolant Temp, Cruise, Pitch Mode Lights will

light for 10 seconds (Figure 12) and Charge Lamp will

remain lit until engine starts. Coolant fan will run for

10 seconds.

Figure 12. Indicator Lights

5. When the Aux1 light turns off, turn ignition key fully

clockwise to the

sTaRT position and listen for engine

to start. Once engine has started release ignition key.

The throttle speed defaults to idle. Let the engine warm

for a few minutes.

6. Repeat this section a few times to get fully acquainted

with the engine starting procedure.

NOTICE

It is recommended that the operation of the Safety Stop

Switch is checked prior to performing any troweling

operations. Doing this will verify that the switch is

working properly contributing to safe operation of the

machine.

OFF ON

PREHEAT

(Unused)

ACC

(Unused)

START

NOTICE

The throttle will default to full speed when the foot pedal

is depressed and operator presence is detected.