beautypg.com

Inspection – Multiquip HTXD6i User Manual

Page 22

background image

page 22 — hTxd6i RIde-ON TROWeL• OpeRaTION maNuaL — Rev. #0 (03/23/12)

inSpectiOn

fueL

1. Determine if the engine fuel is low (Figure 9).

Figure 9. Fuel Gauge

2. If fuel level is low, remove the fuel filler cap and fill with

ASTM D975 No1D or No. 2D diesel fuel. Handle fuel

safely. Motor fuels are highly flammable and can be

dangerous if mishandled.

3. Below are additional technical fuel requirements:

„

The fuel cetane number should be equal to 45 or

higher.

„

The sulfur content must not exceed 0.5% by

volume. Less than 0.05% is preferred. For

electronically-controlled engines, it is mandatory

to use fuel that does not contain 0.1% or more

sulfur content.

In general, using a high sulfur fuel may possible

result in corrosion inside the cylinder. Low sulfur

(300-500 mg/kg sulfur content) or ultra low sulfur

fuel should be used.

„

Never mix kerosene, used engine oil, or residual

fuels with the diesel fuel.

„

The water and sediment in the fuel should not

exceed 0.05% by volume.

„

Keep the fuel tank and fuel-handling equipment

clean at all times.

„

Poor quality fuel can reduce engine performance

and/or cause engine damage.

„

Fuel additives are not recommended. Some fuel

additives may cause poor engine performance.

„

The ash content must not exceed 0.01% by

volume.

„

The carbon residue content must not exceed

0.01% by volume. Less than 0.1% is preferred.

„

The total aromatics content should not exceed 35%

by volume. Less than 30% is preferred.

„

The PAH (polycyclic aromatic hydrocarbons )

content should be below 10% by volume.

„

The metal content of Na, Mg, Si, and Al should be

equal or lower than 1 mass ppm.

„

Lubricity: The wear mark of WS1.4 should be Max

0.018 in (µm) at HFRR test.

„

This trowel can use biodesel fuel. Refer to the

Yanmar Service manual for details.

cauTION

dO NOT smoke while refueling. dO NOT

attempt to refuel the ride-on trowel if the

engine is hot or running.

cauTION

dO NOT store the Ride-On Trowel with fuel in the tank

for an extended period of time. Completely drain the

fuel system (tank, lines, etc.) if the unit is to be put into

long term storage. For shorter or intermediate periods

of time the tank should be filled to avoid condensation

that could cause contamination of the fuel.