C-30HDG PUMP — CONTROL BOX COMPONENTS

Figure 8. Pump Control Box Components

Figure 8 illustrates the location of the major components for the
C-30HDG Control Box. The function of each component is
described below:

1. Throttle Control Switch – This is a variable speed type

control. Holding the control switch to the

left

increases the

engine speed. To place the engine at IDLE speed, hold the
control switch to the

right

and let the engine run for 3-5

minutes.

2. Emergency Stop Button– In the event of an emergency or

to shutdown the engine, push RED emergency stop button
inward. This will stop the engine. To restart engine,
emergency stop button must be released from the stop
position. Simply pull back on the emergency stop button to
release.

3. Ignition Switch – Insert the ignition key here to start the

engine. Turn the key clockwise to the ON position, then
continue turning clockwise to the START position and
release. To stop the engine turn the key fully counter-
clockwise to the

STOP position.

4. Remote Control Input Connector – Insert the remote

control input cable into this connector.

5. Pumping Control Switch – This 3-position switch controls

the pumping of the pump. The

left most

position is for use

with the remote control unit, the

center

position is for off

(prevents pumping), and the

right most

position is for

normal pump operation.

6. Hourmeter– Display's the number of hours the pump has

been in use.

8. Hood Open Lamp– When lit (red) indicates that the hood

has been raised (open) during pumping operation. This
condition will force the engine into idle mode.

7. Check Engine Lamp– When lit (yellow) indicates that an

engine error as occured. See Table 7 for a listing of engine
diagnostic error codes.