beautypg.com

Initial start-up (engine) – Multiquip WM45HCE_rev_0 User Manual

Page 17

background image

WM45HCe pLaSTeR MORTaR MIXeR • OpeRaTIOn and paRTS ManuaL — Rev. #0 (02/04/13) — page 17

initial start-up (enGine)

STOppIng THe engIne

normal Shutdown

1. Move the throttle lever to the IDLE position (Figure 14)

and run the engine for three minutes at low speed.

Figure 14. Throttle Lever (Idle)

2. After the engine cools, push the engine ON/OFF switch

inward to the “

OFF” position (Figure 15).

Figure 15. Engine ON/OFF Switch (OFF)

3. Place the fuel shut-off lever (Figure 16) in the "

OFF"

position.

Figure 16. Fuel Valve Lever (OFF)

emergency Shutdown

1. Move the throttle lever quickly to the

IdLe position, and

place the engine ON/OFF switch in the

OFF position.

CauTIOn

aLWaYS run engine at full speed while mixing.

6. Grasp the starter grip (Figure 11) and slowly pull it out.

The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 11. Starter Grip

7. If the choke lever was moved to the "

CLOSed" position

to start the engine gradually move it to the

"Open"

position (Figure 12) as the engine warms up. If the

engine has not started repeat steps 1 through 6.

Figure 12. Choke Lever (Open)

8. Before the mixer is placed in to operation, run the

engine for several minutes. Check for fuel leaks, and

noises that would associate with a lose component.

9. To begin mixing, place the throttle lever (Figure 13) in

the “

Run” position

.

Figure 13. Throttle Lever (Run)