Ga9.7he— nameplate and decals assy, Caution, Warning – Multiquip GA-9.7HE User Manual

Page 36: Danger, Ga-9.7he, Oil drain fuel drain

background image

page 36 — ga9.7He 60 Hz geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (04/29/10)

ga9.7He— naMeplate and deCals assy.

240

V

120

ON

OFF

ON

OFF

GA-9.7HE

AC CIRCUIT

BREAKER

(for main)

15A

30A

30A

120V

240V

120/240V

START

BUTTON

OPERATION

SWITCH

IDLE CONTROL

SWITCH

for 120V

for 120V

20A

for 240V for 120/240V

AC CIRCUIT BREAKER

AC VOLTMETER

9700

OFF

OFF

35A

35A

S-1123

CAUTION

HOT PARTS can burn skin.

DO NOT touch until the

has sufficiently cooled.

lamp

B90400030

1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the “OFF” position.
3.

. Turn the operation switch to the “ON” position

. After the engine starts, gradually push in the choke knob.
. Run the generator for 3-5 minutes without load.
. Check for any abnormal noise or smell.
. Switch the circuit breaker to the “ON” position.
. When stopping, cut-off the load and allow the unit

to cool for 2-3 minutes before stopping engine.

1 .Turn the operation switch to the “OFF” position.

Pull the choke knob.

4

and push the start button to start the engine.

5
6
7
8
9

0

OPERATING INSTRUCTIONS

D25200040B

To avoid injury,
you MUST read
and understand
operator’s manual
before using this
machine.

Ask for training
as needed.

This machine to
be operated by
qualified
personnel only.

WARNING

Only qualified personnel should
install, use or service this
equipment.

DANGEROUS
GAS

S-4984

WARNING

Only operate machine in well ventilated
areas.
DO NOT inhale exhaust gases.

Only qualified personnel should
install, use or service this
equipment.

S-4985

DANGER

Do not touch output terminals or
internal wiring while unit is operating.
Turn off power before servicing.

Only qualified personnel should
install, use or service this
equipment.

ELECTRICAL
SHOCK
HAZARD

CAUTION

OPERATE AT

3600 RPM ONLY

(

)

FULL THROTTLE

DAMAGE MAY RESULT IF

OPERATED AT LOWER SPEEDS

WARNING

B e f o r e c o n n e c t i n g t h i s
g e n e r a t o r t o a n y b u i l d i n g ’ s
e l e c t r i c a l s y s t e m , a l i c e n s e d
e l e c t r i c i a n m u s t i n s t a l l a n
i s o l a t i o n ( t r a n s f e r ) s w i t c h .

S e r i o u s i n j u r y o r d e a t h m a y
r e s u l t w i t h o u t t h i s t r a n s f e r
s w i t c h .

A91110010

DANGER

Using a generator indoors

.

Utilser un générateur à l’ intérieur VOUS TUERA EN QUELQÙES MINUTES.

CAN KILL YOU IN MINUTES

120

V

O

F

F

GAC-2.2H
POWERED by
Honda Engines

120V
15A

GR PRISE DE
TERRE

AC CIRCUIT BREAKER
INTERRUPTEUR DE
COURANT PRINCIPAL

NEUTRAL BONDED TO FRAME

NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR

211052

120

V

O

F

F

GAC-2.2H
POWERED by
Honda Engines

120V
15A

GR PRISE DE
TERRE

AC CIRCUIT BREAKER
INTERRUPTEUR DE
COURANT PRINCIPAL

NEUTRAL BONDED TO FRAME

NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR

211052

120

V

O

F

F

GAC-2.2H
POWERED by
Honda Engines

120V
15A

GR PRISE DE
TERRE

AC CIRCUIT BREAKER
INTERRUPTEUR DE
COURANT PRINCIPAL

NEUTRAL BONDED TO FRAME

NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR

211052

NEVER use in enclosed or partially
enclosed areas.
Utilisation INTERDITE dans un
espace clos ou partiellement clos.

ONLY use outdoors and away from
open windows, doors, and vents.
Utilisation UNIQUEMENT à l’ extér leur
portes et trous d’ aération

Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
Les gaz d’ échappement contiennent du monoxyde de carbon, un gaz toxique
invisible et inodore.

A90400001

GROUND ROD

FOR EARTH

GROUND

CONNECT TO

BUILDING

GROUND

IF REQUIRED

8 FT. MINIMUM

REFERENCE
NEC 250-52(C)

AC CIRCUIT
BREAKER

120/240V

30A

120V

30A

20A

20A

0N

OFF

IDLE

CONTROL

OPERATION
SWITCH

ON

OFF

FULL POWER
SWITCH

120V

120V/240V

120

V

OFF

21A

GA-6H

6000

GROUND

SCREW

GROUND

CABLE

#8 MINIMUM

DANGER

THE POSSIBILITY EXISTS OF

IF

GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR GROUND POINT.

ELECTROCUTION

FOR FURTHER GROUNDING
INSTRUCTIONS, READ MANUAL

D9531100104

WARNING

Operation of this equipment may create
sparks that can start fires around dry
vegetation.

A spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulation relating
to fire prevention requirements.

A91110010

CAUTION

H

L

Before starting the engine, check that the oil
level is within the indicated operating range.
If the level is

the

mark or

the

mark, it is important to correct before

operating to avoid damage.

above

below

H

L

OIL LEVEL GAUGE

GA-9.7HE

9700

OIL DRAIN

FUEL DRAIN

DANGER

EXPLOSIVE GASES

Cigarette flames or sparks could cause battery to explode. Always
shield eyes and face from battery. Do not charge or use booster cables
or adjust post connections without proper instructions and training.

POISON

CAUSES SEVERE BURNS

KEEP VENT CAPS TIGHT AND LEVEL

Contains sulfuric acid. Avoid contact with skin, eyes or clothing. In
event of accident flush with water and call a physician immediately.

KEEP OUT OF THE REACH OF CHILDREN

1

2

3

4

5

6

7

8

9

10

11

12

S/N 5619690 AND ABOVE