beautypg.com

Ga-6he/ga-6hea — preparation for long term storage – Multiquip GA-6HEA User Manual

Page 28

background image

PAGE 28 — GA-6HE/GA-6HEA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #1 (09/30/05)

Generator Storage

For storage of the generating set for over 30 days, the
following is required:

■ Drain the fuel tank completely, or add STA-BIL to the fuel.
■ Run the engine until the gasoline in the carburetor is

completely consumed.

■ Completely drain the oil from the crankcase and refill with

fresh oil.

■ Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the

cylinder and crank slowly to distribute the oil.

■ Slowly rotate the engine a few times with the starter Rope and

install a new plug.

■ Pull out the starter rope slowly and stop at the compression

point.

■ Clean all external parts of the generating set with a cloth.
■ Cover the generating set and store in a clean, dry place.

GA-6HE/GA-6HEA — PREPARATION FOR LONG TERM STORAGE

This manual is related to the following products: