Generator Storage

For storage of the generating set for over 30 days, the
following is required:

l

Drain the fuel tank completely.

l

Run the engine until the gasoline in the carburetor is
completely consumed

.

l

Completely drain the oil from the crankcase and refill
with fresh oil.

l

Remove the spark plug, pour 2 or 3 cc of SAE 30 oil
into the cylinder and crank slowly to distribute the oil.

l

Slowly rotate the engine a few times with the starter
Rope and install a new plug.

l

Pull out the starter rope slowly and stop at the
compression point.

l

Clean all external parts of the generating set with a cloth.

l

Cover the generating set and store in a clean, dry place.