PAGE 14 — GA-2.3R2 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

GA-2.3R2 — INSTRUMENTATION

CAUTION :

When using a combination of dual
receptacles, total load should not exceed
the rated capacity of the generating set.

Power Outlets

The generator has the following 120 volt 60 Hz (single-phase)
receptacle.

l

Single Phase

One Duplex NEMA (GFCI) 5-20R (120V, 20 Amp)

Main Circuit Breaker (2-Pole 60 Hz)

This 2-pole, 17 amp breaker protects the generator from
short circuiting or overloading from the 120V 60 Hz single
phase load.

Fuel Gauge

The fuel gauge is located on the fuel tank and allows easy
monitoring of the fuel level.

AC Voltmeter

This voltmeter indicates (with a mark) the rated 60 Hz,
single phase output voltage.