SS233 SubmerSible pump • operaTion and parTS manual — rev. #2 (03/22/10) — page 13

trOubleshOOting

Table 2. pump Troubleshooting

Symptom

possible problem

Solution

Pump Fails To Start

Incorrect voltage/amps?

Check that proper voltage (115 VAC

1Ø) is being supplied to the pump.

Also check that there is an adequate

amount of current (amps) to run the

pump. Check power source circuit

breaker.

Check electrical connections?

Inspect power cord.

Blown fuse or defective circuit

breaker?

Replace fuse or circuit breaker. Check

cause of blown fuse or tripped circuit

breaker.

Impeller locked?

Disconnect power cord and check

for clogging and improper impeller

clearance. Unclog pump. Check

overload protection device.

Pump Fails to Deliver Full Output

Twisted or restricted discharge hose? Lay hose flat un-kinked. Remove clog

from hose line.

Clogged pump strainer?

Clean strainer.

Low voltage?

Use a voltmeter to check voltage

while pump is energized. Voltage must

be within ±10%. Check power source

(no load and load). If an extension

cord is used, make sure it has

adequate current-carrying capacity for

the required length.

Table 3. Cable Selection (60 Hz, Single phase operation)

Current in

amperes

load in Watts

maximum allowable Cable length

115 vaC

#10 Wire

#12 Wire

#14 Wire

#16 Wire

2.5

300

1000 ft.

600 ft.

375 ft.

250 ft.

5

600

500 ft.

300 ft.

200 ft.

125 ft.

7.5

900

350 ft.

200 ft.

125 ft.

100 ft.

10

1200

250 ft.

150 ft.

100 ft.

15

1800

150 ft.

100 ft.

65 ft.

20

2400

125 ft.

75 ft.

50 ft.

CAUTION: Equipment damage can result from low voltage.