beautypg.com

R2000h — operation – Multiquip R2000H User Manual

Page 25

background image

R2000H RIDE-ON STATIC ROLLER — OPERATION AND PARTS MANUAL — REV. #6 (11/29/10) — PAGE 25

Water Sprinklers Control

1. If the application requires the wetting of a surface, open

the

water valve

located at the bottom of the roller floor

(Figure 16) to spread the proper amount of water onto the
roller drum at the desired rate that will wet both the front
and rear rollers.

Figure 16. Water Sprinkler Valve (ON)

Normal Shut-Down

1. Place the engine throttle lever in the idle position. Let the

engine idle for 3-5 minutes.

2. If the water valve is open, close it (Figure17)

Figure 17. Water Sprinkler Valve (OFF)

R2000H — OPERATION

3.

Place

the transmission lever (Figure 18) in the

neutral

position

.

Figure 18. Transmission Control Lever (Neutral)

4.

Place

the parking brake lever (Figure 19) in the

set position

.

This will lock the rear roller drum in place, and prevent the
roller from moving. Whenever the operator's seat is vacated,
place the transmission lever in neutral, and set the parking
brake

5. Turn the ignition key (Figure X) to the OFF position remove

key. Store key in a safe place.

Figure 20. Ignition Switch (OFF)

Figure 19. Parking Brake Lever (Set)

6. Place the engine

fuel valve lever

(Figure 20) in the OFF

position.

7. To prevent the roller from moving, place chock blocks under

each roller drum

8. Clean the entire roller with warm water and mild soap. Pay

close attention to the scrapper bar and spray bar holes,
making sure that no dirt or debris is present. Dirt and debris
can cause the sprinkler system to get clogged.

Emergency Shut-Down

1. Turn the ignition key (Figure20) to the OFF position.

2. Place the engine

fuel valve lever

(Figure 11) in the OFF

position.