TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)

Tank not filling

PROBABLE CAUSE

6. Start Switch

7. Timer

8. Pump

9. Solenoid Valve

10. Strainer

1.ON/OFF Switch (This switch must
be in the "ON" position for the refill
circuit to operate.)

2. No water

3. Solenoid Valve

4. Probe

5. Liquid Level Board

REMEDY

Refer to

Service

- Start Switch for

testing procedures. See page 23

Refer to

Service

- Timer for testing

procedures. See page 26 or 28

Refer to

Service

- Pump for testing

procedures. See page 20

Refer to

Service

- Solenoid Valve for

testing procedures. See page 22

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the strainer and check
for obstructions. Clear or replace.

Refer to

Service

- ON/OFF Switch for

testing procedures. See page 19

Be sure water shut-off is open and
that in-line filters or strainers are not
blocking water flow. (Do not con-
fuse water shut-off valve with the
manual fill and drain valve under-
neath brewer).

Refer to

Service

- Solenoid Valve for

testing procedures. See page 22

Refer to

Service

- Probe for testing

procedures. See page 17

Refer to

Service

- Liquid Level Board

for testing procedures. See page 17