Bunn U3A User Manual

Page 11

background image

Page 11

PROBABLE CAUSE

1. Fuse

2. Tank Heater(s)

1. Timer

2. Start Switch

1. Timer

2. Solenoid Valve

3. Lime build-up in swing spout
and pump tubing.

1. Filters

2. Hole in bottom of funnel ob-
structed.

3. Pump - Flow Rate

4. Soft Water

TROUBLESHOOTING (cont.)

PROBLEM

Fuse opening

Water keeps running from swing
spout

Inconsistent coffee yield

Funnels overflow

REMEDY

Refer to

Service -

Fuse for testing

procedures. See page 16

Refer to

Service

- Tank Heater for

testing procedures. See page 25

Refer to

Service -

Timer for testing

procedures. See page 26 or 28

Refer to

Service -

Start Switch for

testing procedures. See page 23

Refer to

Service -

Timer for testing

procedures. See page 26 or 28

Refer to

Service -

Solenoid Valve

for testing procedures. See page
22

Remove swing spout and insert
deliming rod down into pump tub-
ing as far as possible.

Use Bunn

®

filters made for the U3

brewer.

Remove obstruction.

Check pump flow rate with a watch.
Pump flow rate should be approxi-
mately 24 ounces in 15 seconds.
Be sure pump assembly is free of
any obstructions.

When using a water softener, a
coarse grind of coffee may be pre-
ferred. If required, a bypass sys-
tem is available as an optional
feature.

10060.3 070102